Infinity REU-2425W
- 24 -
Issue 2 - 5/07/04 ©Rinnai
There is no direct connection between the mechanical water flow control device with water flow
sensor and the PCB, therefore, there could be occasions when the input required to heat the
water exceeds the capacity of the appliance, and water at a temperature lower than that
requested on the remote control is output. In this case, manually reducing the water flow at the
tap will increase the temperature.
Once hot water is flowing the water temperature thermistor senses the outgoing water
temperature.
The PCB is continually adjusting both the gas input and water flow to maintain a constant
temperature. It also continually monitors the combustion fan rpm adjusting the gas rate to match.
When the hot water tap is turned off, the water flow sensor stops revolving, and the magnetic
pulse ceases, indicating to the PCB that there is no water flowing, in turn the PCB closes the gas
valves. The combustion fan continues to operate for 65 seconds. This is to provide quicker
ignition when the tap is turned on and off in rapid succession, as it removes the need for a pre-
purge cycle, and allows the burner to re-light immediately when a hot water tap is opened again.
The PCB stores data on the calculated incoming water temperature, ready for when the hot water
is turned on again. The data is used to calculate the initial gas flow.
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...