21. Fault Diagnosis
Before carrying out checks marked #, remove power cord from wall plug.
Wiring diagram is on page 30.
Appliance will to operate (even remote control fails to operate)
1) Is the fuse blown?
Fuses are located in plastic holders in the
main harness, on the lower right hand side of
the appliance
Check fuse
a. Remove 240V plug from socket.
b. # Measure resistance to check the
electric fuse (3A).
Normal:
less than 1
If normal, proceed to check item 2)
below.
Faulty:
Replace fuse (5A)
If it blows again, investigate cause of
short circuit.
2) Is the main transformer normal?
Check the transformer
c.
Measure the voltage in between the
red wires of the relay connector (A
1
).
Normal:
AC90 ~ 110 V / 15 ~ 21
If normal, check (d) below.
Faulty:
Check for AC 90 ~ 110 V on the
PCB terminal J
black ~ black
d. Check voltages below at upper PCB
connector A.
Normal:
orange -orange
AC 13 ~ 30V / 1.4 ~ 1.8
brown - grey
AC 30 ~ 50V / 6 ~10
yellow - grey
AC 180 ~ 220V / 0.4 ~ 0.6
If normal, check 3 at top of next page.
Faulty:
Replace the transformer.
Ω
Ω
Ω
Ω
Ω
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...