Infinity REU-2425W
- 49 -
Issue 2 - 5/07/04 ©Rinnai
11) Removal of Gas Control
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
a. Remove the manifold (5 screws), refer
section 8a,b,c.
b. Remove the four (4) screws that hold
the gas connection and gas control in
place. Remove the gas connection.
Handle O-ring carefully. (phillips driver)
c.
Remove one (1) screw that holds the
gas control in place, disconnect
connectors, pull out the gas control.
12) Removal of Heat Exchanger
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
- Isolate Water Supply.
- Drain All Water
a. Remove PCB unit; refer to section 2-a.
b. Remove the heat exchanger water.
connection pipe; refer to section 3-a.
c.
Remove one (1) screw from the
outlet connection clip, to pull out the
hot water supply connection pipe
towards yourself. (Handle O-ring
carefully)
d. Remove the three (3) screws
securing the manifold to the gas
control.
e. Remove four (4) screws that secure
the heat exchanger unit in place.
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...