- 14 -
Issue 2 - 5/07/04 ©Rinnai
10. Dip Switch Positions
Please do not adjust the DIP Switch Positions before reading this information.
The dip switches are provided so that the water heater can be set to different operating
configurations. In some instances such as nursing homes or even domestic situations, it may be
necessary to limit the temperature of the hot water coming from the units.
The set-up configuration for the water heater differs depending on:
• Gas type
• Maximum water flow select
• Temperature limiting requirements
• Alternate type
DIP Switches explained
Top switch settings 1 ~ 8
1: Gas type (used only during conversion)
2: To select maximum water flow volume
4 to 8: To select the temperature with or without remote
connected.
Bottom switch settings 1 ~ 3
1: Factory use (To select the capacity of appliance)
2 & 3: Combustion control
The Infinity REU-2425W model delivers maximum hot
water temperature limited to 50 C, however alternative
PCB for the other maximum temperature of hot 40°C,
43°C, 50°C, 55°C, 60°C, 65°C, or 75°C available.
1. Gas Type
Only alter gas type positions when converting. For conversion instructions refer to page 43.
2. Maximum Water Flow Select
°
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...