Infinity REU-2425W
- 47 -
Issue 2 - 5/07/04 ©Rinnai
c.
Remove four (4) screws from the
water supply connection and remove
connection.
Handle O-ring carefully. (phillips driver)
d. Disconnect electrical connectors and
remove water flow sensor from
control assembly.
6) Removal of Sparker
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
a. Remove one (1) screw that secures sparker
to the attachment plate to remove sparker.
(phillips driver).
b. Disconnect high tension lead
connector.
7) Removal of Combustion Fan
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
a. Detach the sparker, refer to section 4.
b. Remove the three (3) screws that
secure the fan in place, disconnect
connector and pull the fan towards
yourself to remove it.
(phillips driver).
8) Removal of Water Temperature
Thermistor
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
- Isolate Water Supply.
a. Remove the two (2) screws that secure the
thermistor in place to remove the water
temperature thermistor. (phillips driver).
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...