background image

 

 

To achieve better air extraction, we recommend you to switch on the blower a few minutes before starting to cook.  

Leave it on for approximately 15 minutes after cooking or till all cooking smell is completely removed. 

  

Switch control  

Note: Touch the sensor buttons gently to operate this appliance.

 

 

 

On/delay/Off key:  

 

Touch to select on/off. When in operating mode, press once to enter into delay mode; default delay 

timer is 1 minute. Gently slide through the ten-key slider to adjust the delay time: slide to the right to increase timing, slide 
to the left to decrease timing. Maximum delay timing is 10 minutes. When in countdown mode, display will show the time, 
and slider indicator will show the speed. Press the on/off key to exit delay timer mode, and to turn off the blower/fan.  

Lights on/off: 

 Touch to select lights on/off

 

Timer setting: 

When in “off” mode, press and hold the on/off key to enter clock settings. Once the display starts blinking, 

press 

 to decrease hour unit and 

 to increase hour unit. After that, press 

 to confirm and proceed to do the same 

for the minutes display. 

Low speed: Press 

to turn blower on/off at low speed 

Medium speed: Press 

 to turn blower on/off at medium speed 

High speed: Press 

/

 to turn blower on/off at high speed 

Touch slider: Gently slide across to the right to increase blower speed, and across to the left to lower blower speed 
 

Aligning the hood body 

(if necessary)

 

(Fig. 9) 

 

Before attaching hood body to wall, adjust the      

2(two) screws located on the hood body mounting     

points. 

 

Hook the hood body onto the support screws and 

tighten the support screws fully. 

 

Adjust screws to level the hood body. 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

Installation must be performed by qualified personnel 
only.  The manufacturer declines all responsibility for 
improper installation and does not accept responsibility 
for appliance warranty in the event of damage caused by 
incorrect installation. 

 

OPERATION 

 

 

 

 

 

En

glis

Fig. 9 

 

Summary of Contents for RH-C769-MB

Page 1: ...tion Manual 操作 安装说明 Petunjuk Pemakaian Pemasangan Hoạt động Hướng dẫn lắp đặt คู มือการติดตั ง การใช งาน Chimney Hood 塔形烟机 Tudung Hisap Máy Hút Khói Mùi Dòng Chimney เครื องดูดควันชนิดกระโจมติดผนัง RH C779 SB Rinnai Corporation ...

Page 2: ...TABLE OF CONTENTS TABLE OF CONTENTS English Page 1 7 Version 2013 07 ...

Page 3: ...llow young children to play with or operate the appliance Supervise its use by the elderly or infirm Installation and repair should be attempted by qualified technical personnel only It is dangerous to modify any part of this appliance Tampering with electrical connections or mechanical parts can cause operation faults and may put the user at risk Never leave high naked flames under the extractor ...

Page 4: ...no responsibility for complaints attributed to the design and layout of the pipe work Do not flambé or grill with an open flame directly under the extractor hood Flames could be drawn up into the hood by the suction and the grease filters may catch fire Monitor cooking continuously as overheated oil increases the risk of self ignition Do not operate the extractor hood without a grease filter It is...

Page 5: ...ffect any technological improvement or modification without prior notice Ref Qty Product components A 1 Mounting bracket B 1 Inner Duct C 1 Mounting Bracket 2 D 1 Blower Assembly E 1 Charcoal Filter F 1 Oil Cup G 1 Baffle Filter Qty Installation components 4 Screw M4 x 8 5 Screw ST5 x 50 5 10 Expanding Tube Qty Documentation 1 Operation Installation Manual SPECIFICATIONS COMPONENTS Fig 2 Fig 3 Eng...

Page 6: ...e air outlet using a reducing connector not provided Secure both joints appropriately Fig 6 1 Connect pipe to the outdoor duct Wall mounting Fig 7 8 Do ensure that the appliance is mounted on a solid surface which could withstand the appliance s weight Draw a vertical line at the center of the wall From bench top see A draw a horizontal line above minimum installation height level see B Mark a ref...

Page 7: ...off mode press and hold the on off key to enter clock settings Once the display starts blinking press to decrease hour unit and to increase hour unit After that press to confirm and proceed to do the same for the minutes display Low speed Press to turn blower on off at low speed Medium speed Press to turn blower on off at medium speed High speed Press to turn blower on off at high speed Touch slid...

Page 8: ...sary as clogged filters restrict airflow and may cause the motor to overheat Removing and inserting the charcoal filter Take the baffle filter apart hold onto the air intakes and turn slightly Once the charcoal filter turns out of the screw remove directly Cleaning the appliance body Clean the extractor hood using warm detergent solution and a soft damp cloth Wipe dry with a lint free cloth Avoid ...

Page 9: ... mode Motor is running but no airflow Poor exhaust Please contact Rinnai Customer Care Service Whirring sound Foreign object may be in contact with fan blade Please contact Rinnai Customer Care Service Lights are not working Lamps are burnt out Replace the damaged lamps Lamps are loose Tighten the lamps TROUBLESHOOT If problem persists after the above checks please contact Rinnai Customer Care Cen...

Page 10: ...Tel 电话 853 2822 0889 Fax 传真 853 2822 2733 URL 网址 www rinnai com hk mo Thailand ประเทศไทย Rinnai Thailand Co Ltd 61 1 Soi Kingkaew 9 Kingkaew Rd Racha Thewa Bangphli Samutprakarn 10540 Thailand บริษัท รินไน ประเทศไทย จำกัด เลขที 61 1 ซอยกิ งแก ว 9 ถนนกิ งแก ว ตำบลรำชำเทวะ อำเภอบำงพลี จังหวัดสมุทรปรำกำร ประเทศไทย 10540 Tel 66 2 3124330 40 Email lucky02 luckyflame co th URL www luckyflame co th Malay...

Reviews: