background image

Surfaces: 

Wash  with  warm  soapy  water  and  a  soft  sponge.

Never  use  abrasive  detergent,  scouring  pads,  steel 

wool or solvents on any part of this appliance as this 

will cause irreparable damage. 

If washing by hand, soak the aluminium grease filter

(for  ducted  models)  in  warm  detergent  solution  to

simplify the removal of grease. Brush the filter, rinse

thoroughly and leave it to dry before refitting.

If  by  dishwasher,  select  an  appropriate  wash

program. Leave it to dry before refitting. 

Note: 

slight

discoloration of the filter may occur.

Removing and inserting the grease filters:

 To  remove,  depress  the  handle  and  pull  down  at

the same time. 

 To refit, slot the filter into position. Make sure that

handle is visible on the outside. 

Cleaning the appliance body

 

(Refer to diagram below)

A

Remove oil collector

B

Remove rectifier panel

Light replacement  

 

Replace the light bulb with another which has the 

 same characteristics as a higher voltage bulb could 

damage the electrical unit. 

 

Removing and replacing the light bulbs:

o

Remove oil c

ollector

o

Remove rectifier panel

o

Remove aluminium charcoal filter/aluminium filter

with charcoal pellets

MAINTENANCE AND CARE 

Disconnect the power supply cord before carrying out 

any cleaning or maintenance activities. It is important 

to  clean  and/or  replace  the  filters  at  appropriate 

intervals as grease deposits build-up increases the risk 

of  fire.    Do  not  operate  the  extractor  hood  without 

grease filter. 

You  are  strongly  recommended  to  follow  these  safety 

instructions.  The  manufacturer  will  not  be  held  liable 

for any damages to the appliance or any fire hazard  

Due  to  failure  to  observe  the  above  safety 

recommendations. 

.

En

gl

ish

 

C

Remove aluminium grease filter or aluminium grease 

filter with charcoal pellets

D

Remove filter support by removing the 2 screws

E

Remove the fan blade by removing the self-locking nut 

B

A

C

D

E

o

Remove bottom plate

o

Replace the light bulbs

o

Refit bottom plate, filter, rectifier panel and oil 

c

ollector

.

Charcoal filter 

(for recirculation models)

  

The  charcoal  filters  should  be  replaced  when  it  is

noticeably dirty or discolored, usually after 6 to 12

months depending on the conditions of use.

These  filters  are  not  washable  and  cannot  be

restored.  To  ensure  that  this  appliance  functions

effectively,  regular  maintenance  is  necessary  as

clogged  filters  restrict  airflow  and  may  cause  the

motor to overheat.

Removing and inserting the charcoal filter:

o

Remove the oil collector and rectifier panel.

o

Fit in the new charcoal filter.

o

Refit rectifier panel and oil c

ollector

.

Summary of Contents for RH-S259-PBR-T

Page 1: ... Installation Manual 操作 安装说明 Petunjuk Pemakaian Pemasangan Hoạt động Hướng dẫn lắp đặt คู มือการติดตั ง การใช งาน Slim Line Hood RH S259 SSV T RH S259 PBV T RH S259 SSR T RH S259 PBR T Rinnai Corporation English ...

Page 2: ...Page 1 7 English Version 2015 06 TABLE OF CONTENTS ...

Page 3: ... allow young children to play with or operate the appliance Supervise its use by the elderly or infirm Installation and repair should be attempted by qualified technical personnel only It is dangerous to modify any part of this appliance Tampering with electrical connections or mechanical parts can cause operation faults and may put the user at risk Never leave high naked flames under the extracto...

Page 4: ...o responsibility for complaints attributed to the design and layout of the pipe work Do not flambé or grill with an open flame directly under the extractor hood Flames could be drawn up into the hood by the suction and the grease filters may catch fire Monitor cooking continuously as overheated oil increases the risk of self ignition Do not operate the extractor hood without a grease filter It is ...

Page 5: ...t to effect any technological improvement or modification without prior notice SPECIFICATIONS COMPONENTS Fig 2 English A B C D E F G H I REF QTY PRODUCT COMPONENTS A B C D E F G H I 1 1 1 1 1 1 1 1 1 Body Air Outlet Recirculating assembly Duct assembly Lamp Bottom Plate Aluminium Charcoal Filter Rectifier Panel Oil cup Aluminium Charcoal Filter applies to ventilation models For recirculation model...

Page 6: ...on INSTALLATION English Installation 2nd Method According to the diagram below A Remove bottom plate rectifier panel and oil collector as shown B Fix the hood on the cupboard from the inside C Fix the bottom plate rectifier panel and oil collector back D Finished installation Ducted vs Recirculating Mode Ducted Mode In ducted mode cooking fumes are vented outdoors In this mode only aluminum filter...

Page 7: ...ndicator is to remind you to change to new filters To cancel the reminder press and hold the ON OFF button for 4 seconds and the timing display will resume LIGHT Press to turn the light on off Press ON OFF and press to increase motor power press descrease motor power The motor has 4 speed settings OPERATION ON OFF DISPLAY TIMER LIGHT English Delay Timer 3 Minutes When the hood is switched on press...

Page 8: ... power supply cord before carrying out any cleaning or maintenance activities It is important to clean and or replace the filters at appropriate intervals as grease deposits build up increases the risk of fire Do not operate the extractor hood without grease filter You are strongly recommended to follow these safety instructions The manufacturer will not be held liable for any damages to the appli...

Page 9: ...ation mode Motor is running but no airflow Poor exhaust Please contact Rinnai Customer Care Service Whirring sound Foreign object may be in contact with fan blade Please contact Rinnai Customer Care Service Lights are not working Lamps are burnt out Replace the damaged lamps Lamps are loose Tighten the lamps TROUBLESHOOT If problem persists after the above checks please contact Rinnai Customer Car...

Page 10: ...89 Fax 传真 853 2822 2733 URL 网址 www rinnai com hk mo Thailand ประเทศไทย Rinnai Thailand Co Ltd Lucky Flame Co Ltd 61 1 Soi Kingkaew 9 Kingkaew Rd Racha Thewa Bangphli Samutprakarn 10540 Thailand บริษัท รินไน ประเทศไทย จำกัด เลขที 61 1 ซอยกิ งแก ว 9 ถนนกิ งแก ว ตำบลรำชำเทวะ อำเภอบำงพลี จังหวัดสมุทรปรำกำร ประเทศไทย 10540 Tel 66 2 3124330 40 Email lucky02 luckyflame co th URL www luckyflame co th Mala...