RHFE-1004FA CONVERSION

1. Remove two (2) screws that hold the front panel in place.

2. Pull panel forward from the top of unit out about three

inches. Reach inside electrical compartment and unplug
the indicator lamp assembly. Then lift panel up and set it
off the unit. Next remove both side panels.

3. Remove all three (3) gas tubes from the unit. Be careful

not to lose the “O” rings on each end of the gas tubes.
Always ensure there is an “O” ring in each port of the gas
valve and in each of the orifices before reinstalling gas
tubes.

4. Replace all three burner orifices with the proper size

required for gas type being used. Refer to the Technical
Data.

The low fire orifice has a longer shoulder than the high
fire orifices. When converting products, please ensure
you follow instructions in detail. YOU MUST
READJUST MANIFOLD GAS PRESSURE on the
appliance following manufacturer’s instructions and
replace all three burner orifices and reset air shutters.
Failure to follow the manufacturer’s instructions may
result in damage to the unit. If you have not been
properly trained on converting this product, please do
not proceed. Contact a qualified service agency to
perform conversion.

5.

Propane gas unit air shutter settings:

Loosen set screw on air adjustment rods. Adjust all three
air shutters to 100% air, no notches will be showing on the
rods when adjusted correctly. The air rods can be found
directly under each gas line at the combustion chamber.
Retighten set screw once adjustments have been made.

Natural gas unit air shutter settings:

Loosen set screw on air adjustment rods. Adjust the right
rear and left hand air shutters to 100% air, no notches will
be showing on the rods when adjusted correctly. Adjust the
right front air shutter to where three (3) notches are
showing, this is 70% air. The air rods can be found directly
under each gas line at the combustion chamber. Retighten
set screw once adjustments have been made.

6. Ensure all three gas tubes have been re-installed and

tighten. Leak test all gas tube connections to ensure
“O”rings were reinstalled and all fittings have been
retightened.

7. Gas pressure 

MUST

be readjusted when converting from

one gas type to the other. Follow the procedure below
when setting pressures.

Summary of Contents for RHFE-1004FA

Page 1: ...ICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER This appliance may be installed in a after market permanently located manufactured mob...

Page 2: ...00 8 400 HIGH 30 720 29 200 NAT QTY 2 1 PARTS No LPG HI LOW 1004F 2031 B 1 80 1004F 2036 B 1 95 QTY 2 1 PARTS No 1004F 2031 A 0 95 1004F 2036 A 1 20 RHFE 1004FA P Normal Altitude RHFE 1004FA P High Altitude RHFE 1004FA N Normal Altitude RHFE 1004FA N High Altitude MODEL GAS TYPE DIAMETER OF ORIFICES INCHES mm DAMPER ADJUSTMENT LPG NAT 0 037 0 95 0 047 1 20 10 10 10 10 10 10 0 071 1 80 0 077 1 95 7...

Page 3: ...n damage to the unit If you have not been properly trained on converting this product please do not proceed Contact a qualified service agency to perform conversion 5 Propane gas unit air shutter settings Loosen set screw on air adjustment rods Adjust all three air shutters to 100 air no notches will be showing on the rods when adjusted correctly The air rods can be found directly under each gas l...

Page 4: ... the SW1 switch again and change to Low pressure mode PL will be indicated on the display 9 Record your pressure reading on your manometer If the Low fire pressure needs adjusting this can be achieved by pressing the button to decrease the pressure or the button to increase the pressure Set unit to correct pressure as shown the Technical Data 10 Press the Economy button the LED will then display 1...

Page 5: ...3 Press the Economy button to enter the high fire pressure into memory The LED display will indicate 78 14 Press the ON OFF button again The LED display turns blank and the unit returns to the normal OFF mode 15 Reconfirm all pressure settings before putting said unit back into operation Next disconnect your manometer from the unit and reinstall the 1 8 test port plug Leaks test all connections on...

Page 6: ...BAS 8 400 8 400 HAUT 30 720 29 200 NAT QUANTITÉ 2 1 NUMÉRO DES PIÉCES LPG HAUT BAS 1004F 2031 B 1 80 1004F 2036 B 1 95 QUANTITÉ 2 1 NUMÉRO DES PIÉCES 1004F 2031 A 0 95 1004F 2036 A 1 20 RHFE 1004FA P Altitude Normale RHFE 1004FA P Haute Altitude RHFE 1004FA N Altitude Normale RHFE 1004FA N Haute Altitude MODELE TYPE DE GAZ DIAMETRE DES ORIFICES EN POUCES mm REGLAGE AMORTISSEUR LPG NAT 0 037 0 95 0...

Page 7: ...onvenablement formé pour convertir cet appareil veuillez ne pas poursuivre Contactez une société de service compétente pour réaliser la conversion 5 Réglages des volets d aération pour les appareils à gaz propane Desserrez la vis sur les tiges de réglage d air Réglez les trois volets d aération à 100 d air aucun cran n apparaîtra sur les tiges une fois le réglage fait correctement Les tiges d air ...

Page 8: ...PL va s afficher à l écran 9 Enregistrez la lecture de pression sur votre manomètre Si la pression Feu Bas a besoin de réglage ceci peut être réalisé en appuyant sur le bouton pour réduire la pression ou le bouton pour augmenter la pression Réglez l appareil à la pression correcte comme il est indiqué dans les Données Techniques 10 Appuyez sur le bouton Economie Le LED affichera alors 18 indiquant...

Page 9: ...ez sur le bouton MARCHE ARRET de nouveau L écran LED devient vierge et l appareil retourne à une position ARRET normale 15 Reconfirmez tous les réglages de pression avant de remettre l appareil en question en marche Puis débranchez le manomètre de l appareil et réinstallez la prise de test de 1 8 Faites un test de fuite sur tous les branchements une fois que le processus de conversion a été accomp...

Page 10: ... High Injecteur haut Injector Low Injecteur bas Injector High Injecteur haut Injector Low Injecteur bas Conversion Plate Plaque de conversion Conversion Plate Plaque de conversion Visual Reference Référence visuelle Qty Quantité Gas Gaz Part No Numéro de piéce Part Name Nom de la piéce LIST OF CONVERSION PARTS LISTE DES PIECES DE CONVERSION ...

Page 11: ... 10 MEMO ...

Page 12: ...1004F 2092 02 03 Printed in Japan 2005 05 ...

Reviews: