System Parameters
• Some System parameters are accessible but should never be adjusted. This is indicated
with N/A at the description. Ensure factory settings are always maintained at these
parameters
• System parameters that are available at the user level are indicated below
PARA
Description
Range / Explanation
Factory
Setting
User
Access
1
Language
D-German, F-French, I-Italian, GB-English
Rinnai controllers are programmed to English
NOTE: GB = Default at shipment D=Default at System
Reset
GB
Yes
2
Number of
enabled time
programs
P1
Only one time program enabled
P1
Yes
P1-
P3
Three time programs enabled-This would be
applicable for a user that worked rotating shifts, etc
3
Separate
operational
mode control
of CH/DHW
1
Common adjustments for CH and DHW
1
Yes
2
Separate adjustments for CH and DHW-If this is
selected, the operational mode will first ask for CH
or DHW before entering a specific operational
mode. Under normal operation the status bar for
operational mode will not be visible