Reference Manual Rev 1.13
Page 78
004R-646-113
NONE
(Default)
SINGLE
DOUBLE
FLASH
SINGLE: single BEEP
DOUBLE: double BEEP
FLASH: flash display
SOURCE
: Select which weight values the setpoint
checks against the target weight. Options are:
GROSS: Gross weight always
NET: Net weight always
GR.or.NT: Gross or Net depending on which
one is displayed.
ALT.GR: Alternate Gross weight always
ALT.NET: Alternate Net weight always
ALT.G.or.N: Alternate Gross or Net
depending on which one is displayed
IO: Use the external IO
STATUS: Use the instrument status
SETP: Use the setpoint status
REG: Uses a register value
HYS
: Hysteresis defines the amount of weight
required for an active setpoint to become inactive
again.
A value of 0 still allows for 0.5 graduations of
hysteresis.
MASK
: a 32 bit number that is used by the logic
setpoints to match IO1..IO32
DELAY
: If the timing has been set to PULSE this
sets the delay before each pulse.
ON
: If the timing has been set to PULSE this sets
the duration of each pulse.
RDY.TIM
: The time that the scale must be in the
zero band and stable before the SC.REDY setpoint
will become active
TIMING(K404 and K405 only)
: Select the timing
which is applied to the setpoint output. Options are:
LEVEL: Setpoint follows the weight.
EDGE: Setpoint is edge triggered.
PULSE: Setpoint output is pulsed.
LATCH: Setpoint output is latched.
RESET(K404 and K405 only)
: Select which IO is
used as an input to disable the setpoint. Options are
NONE, IO1..IO32
PLS.NUM
: If the timing has been set to PULSE this
sets the number of pulses to be output each time
the setpoint is triggered.
RST.LGC
: This setting determines whether the
input used to reset the setpoint is active when the
value is LOW or HIGH.
SOURCE Values
<OPT>
GROSS
(Default)
NET
GR.or.NT
ALT.GR
ALT.NET
ALT.G.or.N
(*)
NB:
Only for OVER,
UNDER and ZERO setpoints.
IO
(Default)
STATUS
SETP
REG
(***)
NB:
Only for LGC.AND,
LGC.OR and LGC.XOR
setpoints.
HYS Values
<NUM>
0 to 999999
Default: 0
(**)
NB:
Only for OVER, and
UNDER setpoints.
MASK Values
<NUM>
0 to 16777215
Default 0
(***)
NB:
Only for LGC.AND,
LGC.OR and LGC.XOR
setpoints.
DELAY Values
<NUM>
0.040 to 60.000s
Default:
0.040s
(****)
NB:
Only for PULSE
TIMING setpoint.
ON Values
<NUM>
0.040 to 60.000s
Default:
0.040s
(****)
NB:
Only for PULSE
TIMING setpoint.
RDY.TIM Values
<NUM>
0.000 to 60.000 s
Default: 0.000s
(****)
NB:
Only for SC.REDY
setpoints.
TIMING Values
<OPT>
LEVEL
(Default)
, EDGE,
PULSE, LATCH
RESET
Values
<OPT>
NONE
(Default)
, IO1..32