Name
Address
Type
R
W
Description
Setpoint 4 type
A461
H
uint8
A
A
Set setpoint 4 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
Setpoint 4 lock
A462
H
uint8
A
A
Set setpoint 4 lock:
0 is off
1 is on.
Setpoint 4 logic
A463
H
uint8
A
A
Set setpoint 4 logic:
0 is high
1 is low.
Setpoint 4 alarm
A464
H
uint8
A
A
Set setpoint 4 alarm:
0 is none
1 is single beep
2 is double beep
3 is continuous beeping
4 is flash the display.
Setpoint 4 source
A466
H
uint8
A
A
Set setpoint 4 source:
0 is gross weight
1 is net weight.
Setpoint 4 Target
A468
H
int32
A
A
Set setpoint 4 target.
Setpoint 4 Hysteresis
A469
H
int32
A
A
Set setpoint 4 hysteresis.
Setpoint 4 in flight
A46A
H
int32
A
A
Set setpoint 4 in flight.
Setpoint 4 Timing
A470
H
uint8
A
A
Setpoint 4 timing:
0 is level
1 is edge
2 is latch
3 is pulse.
Setpoint 4 Reset
A471
H
uint8
A
A
Setpoint 4 rest:
0 is none
1 is reset A
2 is reset B.
Setpoint 5 type
A481
H
uint8
A
A
Set setpoint 5 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
90
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...