505.839.3010
Appendix B
Page B-5
Verify Factory Parameter Settings
1. Press “SEL” for 3 seconds until the SV light
comes on and the row displays the casting
set-point. Release the button.
2. Turn the J-2
r
off and then on again.
3. Repeat all the above steps to check all
the settings. Some parameters are linked
to other parameters, so the setting must
be verified.
Important: Use care when stepping through
the parameters to be sure you don’t
mistakenly change a value. All values must
be correct for the controller to work properly.
Close dSP Factory Settings
1. After checking all the settings, push the
down arrow (
∨
) again until you see dSP1 (or
press “SEL” 9 seconds until you see “P-n1” and
then press the down arrow (
∨
) until you see
“dSP1”.
2. Continue setting the values from the dSP
factory settings chart below.
Display Setting
dSP1
251
dSP2
127
dSP3
255
dSP4
255
dSP5
255
dSP6
255
dSP7
127
dSP factory settings, closed
3. Turn off the J-2
r
. The correct settings are
now permanently stored in the controller.
The machine is ready for operation.
Important: Remember to re-enter your
casting temperature set-point and your
casting balance after you have made any
changes to your J-2
r
programming settings.