Page
24
User Manual
GARDTEC
872
6)
The display will show
L -
7)
If you wish to remove other zones return to step 5
Or
To escape press 0 the display will show
R D
(flashing).
8)
Press YES to start setting the system.
9)
Exit the premises or retire to an unprotected part of the system. At the end
of the exit time the exit tone will stop provided the system was clear.
Note:
Zone remove is only effective for the one set.
Testing The System
(Master & Main codes only)
1)
With the display showing
T M
2)
Enter a Master or Main level code, the display will show
R D
(flashing).
3)
Press NO twice, the display will show
D
(flashing).
4)
Press YES, the display will show
A
press YES if you wish to test all areas
(
or
press NO until the area you wish to test is displayed then press YES)
5)
The display will show
A
(if all zones are clear).
6)
Whilst in test mode:-
Pressing 6 will silence the internal sounders
Pressing 4 will toggle the strobe On / Off
Pressing 9 will toggle the Bells On / Off
7)
When you have finished testing the system press 0 twice to return to the
Unset condition.
PR5407.qxd 05/11/2003 15:12 Page 24