Performing a Walk Test
A walk test checks the detection ability of all detectors (PIR and Magnetic Contact detectors)
in all zones, to ensure correct operation. Test results are displayed on the keypad. A walk
test can be a relatively a quick procedure, depending on the scope of the installation and
premises, however if needed, up to 60 minutes is allotted for the test. The following walk
tests can be performed:
•
Full Walk Test:
This test displays the activated zones (the zones where all detections
occurred) and the types of detection.
•
Quick Walk Test:
This test displays the non-activated or open ("not-ready") zones (the
zones where detections didn't occur).
NOTES:
•
Both full and quick walk tests must be performed with the system unarmed.
•
A walk test cannot be performed using a Slim keypad
➢
To perform a full or quick walk test:
1.
Ensure the system is unarmed.
2.
At the keypad, enter your Grand Master code, and then press
OK.
3.
Scroll to
Maintenance
and then press
OK.
4.
Scroll to
Walk Test
and then press
OK.
5.
Scroll to either
Full Walk Test
or
Quick Walk Test,
and then press
OK;
MAKE WALK
TEST AND HIT ANY KEY display.
6.
During the allotted time period of 60 minutes, walk through all the zones in order to
trigger activations from all the detectors in those zones.
NOTE:
During the last five minutes of the time period, the keypad used to initiate the
test will indicate that the time period is about to end.
7.
When you have finished walking through the zones, press any key on the keypad to end
the test; the results display on the keypad.
Testing MS Communication
This tests the communication between the system and the monitoring station(s). See