01/2022
Page 86
5IN2933
Requested / initiated from: Slim keypad
Each key press
1 short beep
No sound
Arming / disarming
1 long beep
Armed = 1 squawk
Disarmed = 2 squawks (or 4 if
disarmed after an alarm)
Requested / initiated from: LightSYS keypad, Elegant, Panda keypad
Operation / event
Sounds from keypad
Sounds from siren
Intrusion alarm
Fast beeping
Siren sound (fast beeping)
Fire alarm
Fast beeping
Repeated sequence of 2 siren
beeps followed by short
interval
Duress Disarming
alarm
No sound
(1)
No sound
(1)
Emergency alarm
A single beep
No sound
Arming / disarming
Long "confirmation" beep (can
be installer-configured to be
without sound).
Armed = 1 squawk
Disarmed = 2 squawks (or 4 if
disarmed after an alarm)
Confirm operation
Long "confirmation" beep
No sound
Reject command /
incorrect operation
3 fast beeps
(2,3)
No sound
Chime sound
Long beep
(4)
None
Entry Delay countdown
Slow repeating beeps until end
of delay period
(2)
Fast beeps at
end of delay period.
No sound (unless installer-
configured)
Exit Delay countdown
Slow repeating beeps until end
of delay period
(2)
Fast beeps at
end of delay period.
No sound (unless installer-
configured)
Footnotes:
1.
As defined by the installer, during system installation.
2.
Keypad beeps may be enabled/disabled by user (see
3.
Press the OK button on the keypad for two seconds to stop fault beeps
4.
As defined by the installer, for any intrusion zone violated when the system is
disarmed. It can be disabled when not required
.
Summary of Contents for LightSYS Plus