LuMIN8 Installation Instructions
10
Sounder Trigger Connection - Serial Mode, ProSYS FreeCom
BUS (Serial) connection to ProSYS FreeCom
BLK
COM
BELL
+
YEL
GRN
+
-
HOLD
GRN
YEL
PRO BUS
LuMIN8 Sounder
ProSYS FreeCom
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
DIPSWITCH
SCB/SAB
A1
A2
A3
BUS/STD
PRO/ACT
MON/NM
TMF/EXT
Sounder defined
as unit No. 2
BUS
Sounder Trigger Connection - Serial Mode to GT Control Panel, Parallel Mode
+
-
HOLD
TMPR
TRIG
ACT BUS
LuMIN8 ID 2
GT Control Panel
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
DIPSWITCH
SCB/SAB
A1
A2
A3
BUS/STD
PRO/ACT
MON/NM
TMF/EXT
Sounder defined
as unit No. 2
+
-
BELL
BELL
HOLD
SAB
TMP
+
-
HOLD
TMPR
TRIG
ACT BUS
LuMIN8 ID 1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
DIPSWITCH
SCB/SAB
A1
A2
A3
BUS/STD
PRO/ACT
MON/NM
TMF/EXT
2 Lumin8 Sounders connection to GT Panel in
Serial mode using power supply for unit 2
Sounder defined
as unit No. 1
12V PSU
+
-
Note
: In Sounder 2 set SW8 to ON
position to get a low current
consumption. T
he sound output will
be reduced to *106dB 90mA
Commissioning
Before powering the unit, ensure all dipswitches are in the required position. After the wiring has been
completed the system should be powered up. Note that if the unit has a trigger (including tamper) it will
sound for four seconds and then it will cut off (engineer test). The sounder may then only be re-
triggered by clearing the original trigger (or tamper). This four second timer is only available at power
up.
Notes:
1. Sounder cut-off time is 15 minutes unless the supply voltage is less than 13V when triggered the cut-off time is 5
minutes.
2. Strobe will flash at 1.25Hz unless the control panel appears to be running on battery; if so the strobe will flash once
every 5 seconds.