background image

LuMIN8 Installation Instructions 

15 

 

 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and 
(2) This device must accept any interference received, including interference that may cause undesired operation. 
Changes or modifications to this equipment which are not expressly approved by the party responsible for compliance (RISCO Group's.) could void the user's authority to operate the equipment. 

FCC Note 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation. 
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined 
by turning the equipment on and off, the user is encouragedto try to correct the interference by one or more of the following measures: 
• Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and the receiver. 
• Connect the equipment into an outlet on to a different circuit from that to which the receiver is connected. 
• Consult the dealer or an experienced radio/TV technician for help. 
 
For the FCC Supplier's Declaration of Conformity please refer to our website

www.riscogroup.com

 

 

EMC Compliance Statement 

Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and 
other relevant provisions of Directive 2014/30/EU. For the CE Declaration of Conformity please refer to our 
website: www.riscogroup.com 

 

RISCO Group Limited Warranty 

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects 
in materials and workmanship under normal use for 24 months from the date of production. Because 
Seller does not install or connect the product and because the product may be used in conjunction with 
products not manufactured by the Seller, Seller cannot guarantee the performance of the security 
system which uses this product. Seller's obligation and liability under this warranty is expressly limited 
to repairing and replacing, at Seller's option, within a reasonable time after the date of delivery, any 
product not meeting the specifications. Seller makes no other warranty, expressed or implied, and 
makes no warranty of merchantability or of fitness for any particular purpose. 

In no case shall seller be liable for any consequential or incidental damages for breach of this or any 
other warranty, expressed or implied, or upon any other basis of liability whatsoever. 

Seller's obligation under this warranty shall not include any transportation charges or costs of 
installation or any liability for direct, indirect, or consequential damages or delay. 

Seller does not represent that its product may not be compromised or circumvented; that the product 
will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the 
product will in all cases provide adequate warning or protection.  

Seller, in no event shall be liable for any direct or indirect damages or any other losses occurred due to 
any type of tampering, whether intentional or unintentional such as masking, painting or spraying on 
the lenses, mirrors or any other part of the detector. 

Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, 
robbery or fire without warning, but is not insurance or a guaranty that such event will not occur or that 
there will be no personal injury or property loss as a result thereof. 

Consequently seller shall have no liability for any personal injury, property damage or loss based on a 
claim that the product fails to give warning. However, if seller is held liable, whether directly or 
indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause 
or origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be 
complete and exclusive remedy against seller. 

No employee or representative of Seller is authorized to change this warranty in any way or grant any 
other warranty. 

WARNING:

 This product should be tested at least once a week.

 

Summary of Contents for Lumin8 4012

Page 1: ...Installation Instructions Models Lumin8 4012 Lumin8 Delta 4022...

Page 2: ...LuMIN8 Installation Instructions 2...

Page 3: ...anel Parallel Mode 9 Sounder Trigger Connection Serial Mode GT Control panels 9 Sounder Trigger Connection Serial Mode ProSYS FreeCom 10 Sounder Trigger Connection Serial Mode to GT Control Panel Para...

Page 4: ...e circuit board contained within the encapsulated module produces high voltages that may be present at the piezo head connections 1 Open the screw cover located at the bottom of the sounder and unscre...

Page 5: ...Sound ON Low Sweep tone OFF High Sweep tone SW4 A3 Used to define Engineer Maintenance Mode 2 options available ON The Engineer may disable the box tamper built in bell tamper ring by removing the 12V...

Page 6: ...ollowing explains the various wiring and connection procedures that must be performed when wiring the sounder HOLD TMPR TRIG ACT BUS STB TMPF FAULT SET YEL GRN PRO BUS LAMP Terminal Description HOLD T...

Page 7: ...ctivating the external LAMP The LAMP is activated when it is connected between LAMP and Hold Pro BUS Serial Mode SW5 and SW6 ON Lamp controlled from ProSYS BUS no connection required Sounder Trigger C...

Page 8: ...Mode LuMIN8 Sounder SW7 ON An internal 4K7 resistor is connected between the TRIG terminal and the HOLD 0V terminal SW8 ON a short between the TMPF terminal to HOLD 0V HOLD TMPR TRIG ACT BUS STB TMPF...

Page 9: ...ON OFF ON OFF ON OFF OFF ON SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DIPSWITCH SCB SAB A1 A2 A3 BUS STD PRO ACT MON NM TMF EXT R1 Wiring for 2 Monitored LuMIN8 connected to GT Panels Stand Alone Mode 2K2 HOLD...

Page 10: ...W4 SW5 SW6 SW7 SW8 DIPSWITCH SCB SAB A1 A2 A3 BUS STD PRO ACT MON NM TMF EXT 2 Lumin8 Sounders connection to GT Panel in Serial mode using power supply for unit 2 Sounder defined as unit No 1 12V PSU...

Page 11: ...A Strobe light Surface Light Technology SMT LED Strobe lens Polycarbonate available in amber red or blue Strobe flash rate 60 times per minute maximum Back up battery rechargeable Ni MH rechargeable 8...

Page 12: ...xecom D A B C S A1 Omnicron SCB 0V Bell Siren Bell Siren SCB RT Strobe Castle HO HO B ST S Ademco Bell Tamp Bell Bell Bell Tamp R STRB Non Monitored Mode Wiring for Castle Panels Stand Alone Mode LuMI...

Page 13: ...ngle Piezo 50m Twin Piezo LuMIN8 1 SAB 6 Core Cable Control Panel Max Distance 300m LuMIN8 2 SCB 6 Core Cable Control Panel Max Distance 71m Single Piezo 50m Twin Piezo LuMIN8 1 SAB 6 Core Cable LuMIN...

Page 14: ...LuMIN8 Installation Instructions 14 Appendix 3 LuMIN8 Lamp Spotlight Installation Also represents model Lumin8 Delta 4022 1 2 3 4 5 3mm 6 7 8...

Page 15: ...ll or connect the product and because the product may be used in conjunction with products not manufactured by the Seller Seller cannot guarantee the performance of the security system which uses this...

Page 16: ...cn riscogroup com Spain Tel 34 91 490 2133 E mail support es riscogroup com USA Tel 1 631 719 4400 E mail support usa riscogroup com France Tel 33 164 73 28 50 E mail support fr riscogroup com Israel...

Reviews: