152
ProSYS Installation and Programming Manual
Report Codes: Accessory Code
Quick Keys
Parameter
Default
66
00
33
22
Printer Trouble Restore
00
Enter the Printer module's 1-digit physical ID.
1. Enter the 2-digit Report Code for the restore to normal of the detection of
printing difficulty (see above).
2. If this event is not to be transmitted, use the
00
default.
3. Press
the
key to return to the previous programming level.
66
00
33
33
Printer Buffer Full
00
Report Code for a full buffer in the module (a printing difficulty). The event will
be sent if the buffer is full (above 75% of its capacity).
66
00
33
44
Printer Buffer Full Restore
00
Report Code for the restoral-to-normal of the module's buffer. The restoral will
occur once the buffer decreases to 75% of its capacity.
66
00
44
Wireless Button
00
Press
[4]
to access each sub-category, as shown below.
66
00
44
11
Wireless Button Low
Battery
00
Report Code for low battery condition.
66
00
44
22
Wireless Button Low
Battery Restore
00
Report Code for correction of low battery condition.
66
00
55
Siren Trouble
00
Press
[5]
to access each sub-category, as shown below.
66 00 55 11
Trouble
00
Report codes for BUS siren trouble:
[1] Low Battery: report code for low battery condition from siren x.
[2] Bell: report code that indicates a siren trouble.
[3] Auxiliary Fail: report code that indicates an auxiliary trouble on the siren x.
66 00 55 22
Trouble Restore
00
Report codes for BUS siren trouble restore:
[1] Low Battery: report code for the restore of a low battery condition from
siren x.
[2] Bell: report code for the restore of a siren trouble.
[3] Auxiliary Fail: report code that indicates an auxiliary trouble restore on
siren x.
66
00
66
GSM Trouble
00
The GSM report codes menu.