ProSYS Installation and Programming Manual
167
Accessories: Add Delete Module
Quick Keys
Parameter
Default
Range
2. Use
the
/
or
/
keys to position the cursor
over
ID=1
and type in the Bus Zone ID number that you are assigning or
deleting.
NOTE:
Make sure that the detector's physical ID number is identical to the ID number you
select during programming
.
3. Place the cursor over the
TYPE
field, and press the
/
key
to toggle and choose from the options provided, as follows:
NONE
OPR12 (WatchOUT
PIR
detector)
ODT15 (WatchOUT DT detector)
WatIN (WatchIN DT detector)
ILUN3 (Industrial Lunar Grade 3 detector)
iDTG3 (iWISE DT Grade 3 detector)
iQDG3 (iWISE QUAD Grade 3 detector)
4. Press
/
to confirm. Repeat the process for the other BUS
detectors.
NOTE:
If BUS detector is found and NONE has been selected, Press
/
to
return to the prior display -OR- Press the
/
key to select [Y] YES
and press
/
to confirm the delete
.
77
11
99
66
GSM/GPRS Module
1. Press [6]. The following display appears:
GSM MODULE:
TYPE=NONE
GSM MODULE:
TYPE=NONE
2. With the cursor positioned at the
TYPE
field, use the
/
key
to toggle and choose the
GSM
option.
3. Press
/
to store your choice.
NOTE:
If GSM/GPRS module is found and NONE has been selected, Press
/
to return to the prior display -OR- Press the
/
key to
select [Y] YES and press
/
to confirm the delete.