186
ProSYS Installation and Programming Manual
3
Enter a number (between 00-37) to define the starting card code position. This
position determines where the system will start reading the 8-digit code on the card.
4
Press
/
.
99
33
Access Control: Special Code
The Special Code menu enables you to assign codes to the arm cards defined in the system
in order to perform operations in addition to opening the doors (such as arming the system).
Users can arm the system only after the Arm Code has been entered, as this code informs
the system that its about to be armed. This option is only applicable for readers that include a
keypad with the following technology combinations:
Keypad and proximity
Keypad and magnetic
To access the Special Code menu:
1
Access the Access Control menu, as described on page 182.
2
From the Access Control menu, press
[3]
to access the Special Code menu options. The
following display appears:
3
Access and configure the parameters in the Special Code menu, as follows:
Access Control: Special Code
Quick Keys
Parameter
Default
Range
99
33
11
Arm Code
99
00-99
Defines an Arm code that enables a user to arm the system. The system will
be armed after the defined Exit Delay time period (refer to page 47).
Press
[1]
and then enter a two-digit Arm code.
4. Press
/
.
99
33
22
Instant Arm
98
00-99
Defines an Arm code that enables a user to arm the system immediately,
regardless of the Exit Delay time period.
Press
[2]
and then enter a two-digit Arm code.
5. Press
/
.