56
ProSYS Installation and Programming Manual
11
22
37
37
Prox AM=Tamper
NO
YES/NO
Used to determine the operation of the proximity anti masking detection
indicated by the MW channel in the WatchOUT DT detector.
YES
: Proximity anti mask detection will activate the tamper alarm.
NO
: Proximity anti mask detection will be regarded as a trouble event.
Note that Proximity AM operates for approximately 2.2 seconds when the
detector is approached in close proximity.
Ensure that Prox Anti Mask has been enabled when configuring the
WatchOUT DT BUS zone parameters ([2][0][3][zz][8]).
11
22
38
38
Siren Auxiliary = Tamper
NO
YES/NO
This parameter relates to the BUS siren.
YES:
A siren auxiliary trouble will be regarded as tamper alarm by the system.
NO:
A siren auxiliary trouble will be regarded as trouble by the system.
11
22
39
39
GSM Pre Alarm Indication
NO
YES/NO
Related to the GSM/GPRS module. This parameter specifies if the ProSYS
will send a pre alarm message to the GSM when an entry delay starts.
YES
: The ProSYS will send the GSM a pre alarm signal at the beginning of
the entry delay. If the GSM does not receive a cancellation signal from the
ProSYS at the end of the entry time, it will send a burglar message report to
the MS.
NO
: No pre alarm indication is initiated to the GSM.
11
22
40
40
Disable GSM Battery
NO
YES/NO
This parameter indicates if there will be a fault indication when no backup
battery is connected to the GSM/GPRS module.
NO
: The GSM low battery indication is enabled. Use this option when the
GSM is installed in its own casing and its backup battery is connected.
YES
: GSM low battery indication will be disabled. Use this option when the
GSM module in installed inside the casing of the ProSYS. No battery is
connected to the GSM battery connectors.