WatchIN Installation Manual
18
Zones Miscellaneous: BUS Zone
Quick Keys
Parameter
Default
[2][0][3][zzz]
[1]
LEDS
3 LEDS
Defines the LEDS operation mode
[2][0][3][zzz]
[1][1]
Off
Disables the LEDS operation
[2][0][3][zzz]
[1][2]
Red Only
Only the Red led will operate. This option is highly recommended to avoid
the possibility that the intruder will “Learn” the detector behavior.
[2][0][3][zzz]
[1][3]
3 LEDS
All 3 LEDs will operate.
[2][0][3][zzz]
[2]
Detection Sensitivity
Normal
Defines the sensitivity of the detector(MW + PIR)
[2][0][3][zzz]
[2][1]..[4]
Sensitivity Options
1) Low
2) Medium
3) Normal
4) ACT
(Anti-Cloak™ Technology)
[2][0][3][zzz]
[3]
MW Range
Trimmer
Defines the microwave channel range (maximum range - 27m)
[2][0][3][zzz]
[3][1]..[7]
MW Range options
1) Minimum
2) 20%
3) 40%
4) 60%
5) 80%
6) Maximum
7) Trimmer (MW is
defined by the trimmer
setting on the PCB)
[2][0][3][zzz]
[4]
Alarm Logic
PIR and Microwave
Determine the detector’s logic of defining an alarm.
[2][0][3][zzz]
[4][1]
PIR and Microwave
Alarm is activated when both PIR and MW channels detect an alarm
(AND Logic)
[2][0][3][zzz]
[4][2]
PIR or Microwave
An alarm is activated when either PIR or MW channels detect an alarm (OR
Logic)
[2][0][3][zzz]
[5]
Lens Type
Wide Angle
Defines the actual Lens of the detector
[2][0][3][zzz]
[5][1]..[2]
Lens Type Options
1) Wide Angle 2) Barrier
[2][0][3][zzz]
[6]
Anti-Mask
Enable
Defines the operation of Anti Masking detection
[2][0][3][zzz]
[6][1]..[2]
Anti-Mask Options
1) Disable 2) Enable (Default)
Quick Keys
Parameter
Default
[2][0][3][zzz]
[7]
Arm/Disarm
No
Defines the operation of the LEDs and the anti masking detections while the
detector is armed
[2][0][3][zzz]
[7][1]
No
AM (Anti masking) is enabled
LEDs behave according to the LEDs parameter definition
[2][0][3][zzz]
[7][2]
Yes
AM (anti masking) is disabled
LEDs are disabled
[2][0][3][zzz]
[8]
Green line Yes
The WatchIN includes a Green Line feature that follows environmental
Summary of Contents for WarchIN RK325DT