WatchIN Installation Manual
7
TRIPLE EOL Jumpers
TRIPLE
EOL Jumpers
J4
TAMPER EOL
J5
ALARM EOL
1K
2.
2K
4.7
K
6.8
K
5.
6K
FAULT/AM EOL
12K
J6
SHORT
AM/FAULT
J25
Jumpers J4 and J5 allow the selection of Tamper
and Alarm resistance (1K, 2.2K, 4.7K, 5.6K, 6.8K)
according to the control panel (see Figure 6
below). Jumper J6 allows the selection of 12K for
Fault/Anti-Mask.
Follow the terminal block connection diagram in
Figure 6 when connecting the detector to a
Double/Triple End Of Line (DEOL/TEOL) Zone.
TAMPER EOL (J4) ALARM EOL (J5)
Short AM/FAULT (J25)
FAULT/AM EOL (J6)
No Resistor
(Factory Settings)
TAMPER
EOL
JUMPERS
J4
1K
2.2K
4.7K
5.6K
6.8K
ALARM
EOL
JUMPERS
No Resistor
(Factory Settings)
J5
1K
2.2K
4.7K
5.6K
6.8K
AM
/
FAULT
J25
Open
Short
FAULT
/
AM
EOL
JUMPERS
J6
Open
Short
12K
FAULT/AM
+
-
SET/
UNSET
AM
N.O. N.C.
FREE
(GRN)
LED
ENBL
TEST
ALARM
EOL
JUMPERS
No Resistor
(Factory Settings)
ALARM
N
.
C
.
TAMPER
SHORT AM/FAULT
FREE
(YEL)
COM
TAMPER
J5
FAULT
/
AM
EOL
JUMPERS
J6
AM
/
FAULT
J25
1K
2.2K
4.7K
5.6K
6.8K
-
PANEL TEOL
PANEL DEOL
No Resistor
(Factory Settings)
TAMPER
EOL
JUMPERS
J4
1K
2.2K
4.7K
5.6K
6.8K
Open
Short
Open
Short
12K
Figure 6