Assembly instructions - VIGILANT 500
4 - Fix the upper flange using the round head screws provided.
Attention: The screw heads must be placed on the upper part of the
flange
(inside the case).
This way the foundation case is complete. See figure alongside.
5 - Carry out the excavation in the ground with the measurements indicated
in the image alongside and prepare a suitable draining foundation. Insert
the foundation case in the excavation.
Attention: The case must rest on the bottom of the excavation and
must be perfectly vertical - check this by placing a spirit level on the
upper flange.
Insert the 40 mm diameter corrugated sheath in the case using the metal
guide. Fix the case with cement.
6 - Fit the clamps as in the figure locking them in position with the washer
and the M10 hexagonal head screw. Fold them according to the foundation.
Attention: Make sure, during the cast, that the fixing plug you find un-
der the cramp-iron is completely covered with concrete. Using a spirit
level, check if the flange plane is horizontal.
800
800
300/400
Cement
Hole 800x800x1000 mm with draining foundation
Corrugated
sheath
300
Fine
sand
300
Gravel