9 - 4
CZ80 / CV860 Rev. .0
CHAPTER 9: CLAMP UNIT
Clamp motor
Clamp sensor
Mounting screw
Mounting screw
Mounting screw
DISASSEMBLY
1. Clamp Unit
REMOVAL
) Turn OFF the machine power and remove the Rear cover. (M3x8 screws: 5 pcs.)
2) Open the PCB bracket on the rear of the machine. (M3x8 screws; 4 pcs)
3) Unplug the wire harness connectors of the Clamp motor and Clamp sensor.
4) Remove the mounting screws of the Clamp unit and remove the unit. (M3x6 screws; 3 pcs)
Precaution in Assembly
1) Match the positioning hole against the positioning pin in attaching the Clamp unit back on the
machine.
RISO Inc. Technical Services & Support