10 - 5
CZ180 / CV1860 Rev. 1.0
CHAPTER 10: MASTER REMOVAL
Compression motor
Master removal FULL detection sensor
5. Disposed Master Compressing Mechanism
1) Compression Motor
As the master is removed from the Drum and transferred into the Master disposal box, the
Compressing motor activates and rotates the Master compression plate down to compress the
disposed master in the Master disposal box. The Compression motor stops when the Actuator
disk on the Master compression plate escapes from the light path of the Master compression
HP sensor. The Compression motor then rotates in the opposite direction and lifts the Master
compression plate back to the home position.
2) Master Full Detection Sensor
If the Master full detection sensor does not detect Master compression plate at all during the
disposed master compressing movement, the machine assumes that the Master disposal box is
full.
6. Master Disposal Box Set Mechanism
1) Disposal Cover Set Switch
Disposal cover set switch checks the presence of the Master disposal box and whether the
Master disposal upper cover is opened or closed. When the Master disposal box is set in the
machine, it pushes the Switch lever and lifts the Disposal cover set switch.
The lifted Disposal cover set switch can then be pressed when the Master removal unit is closed.
2) Master Removal Unit Safety Switch
As with the Disposal cover set switch, the Master removal unit safety switch is lifted when the
Master disposal box is set in the machine. The lifted Master removal unit safety switch can then
be pressed when the Master removal unit is closed.
RISO Inc. Technical Services & Support
US.RISO.COM