10 - 12
CZ180 / CV1860 Rev. 1.0
CHAPTER 10: MASTER REMOVAL SECTION
View of the Master compression plate hanging down.
Master removal motor
Master removal motor cover
Master removal motor
7. Master Removal Motor
Precaution in Removal
1) Watch out for the Master compression plate, which hangs free when the Gear to the Master
compression motor is removed.
REMOVAL
1) Turn OFF the machine power and remove the Master removal upper cover. (M3x8 screws; 2 pcs)
2) Remove the Gear cover (rear). (M3x6 screws; 2 pcs)
3) Remove the Gear and Gear-35. (6mm dia. E-ring; 1 pc) (M3x12 screw; 1 pc)
4) Remove the Gear cover (front). (M3x6 screws; 2 pcs)
5) Remove 2 pcs of Gears and the Belt. (4mm dia. E-ring; 2 pcs)
6) Remove the Master removal motor cover. (M3x6 screws; 2 pcs)
7) Remove the cord clamp of the Master removal motor, unplug the motor wire harness connector,
and remove the Master removal motor. (M3x5 screws; 2 pcs)
Precaution in Assembly
1) When mounting the Gear back on the unit, make sure that the Master compression plate is
positioned level against the Master removal housing.
RISO Inc. Technical Services & Support
US.RISO.COM