11 - 8
CZ180 / CV1860 Rev. 1.0
CHAPTER 11: SCANNING SECTION
Stripper solenoid
Link assembly
Solenoid plunger
Stripper solenoid
2. AF Stripper Solenoid
REMOVAL
1) Turn OFF the machine power and remove following parts.
Master removal upper cover (M3x8 screws; 2 pcs)
Scanner upper frame cover (M3x8 screws; 4 pcs)
Scanner unit cover (M3x8 screws; 4 pcs)
2) Unplug the wire harness connector of the AF stripper solenoid.
3) Open the Master making unit and remove the mounting screws of the AF stripper solenoid to
detach the solenoid. (M3x6 screws; 2 pcs)
Precaution in Assembly
1) Make sure to hook the Link onto the plunger of the Solenoid.
Operation check of the Solenoid
1) Pull the solenoid plunger to confirm that the Shutter comes down when the plunger is pulled.
RISO Inc. Technical Services & Support