CHAPTER 13: PANEL MESSAGE
6. Detailed List of Panel Messages
Error Type
P01 [Main motor lock]
Description
P01-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Press Reset Key
Error Point
Error Conditions
520
Main encoder sensor does not go ON/OFF within 10 milliseconds after the main motor activates.
521
Position-A sensor status does not change even after 3,033 pulses after the main motor activates.
524
Clamp unit is not at the home position while the print drum is in operation (except during master
disposal).
537
Print drum failed to stop at Position-A.
Error Type
P02 [Elevator motor lock]
Description
P02-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Press Reset Key or turn OFF and ON the power.
Error Point
Error Conditions
400
Both the upper and lower limit sensors are ON at the same time.
401
Overload current was detected in the elevator motor.
404
The lower-limit sensor does not go OFF within 2 seconds after the elevator motor operates in the
raising direction from the lower-limit position.
405
The upper-limit sensor does not go ON within 12 seconds after the elevator motor operates in the
raising direction.
406
The upper-limit sensor does not go OFF within 2 seconds after the elevator motor operates in the
lower direction from the upper-limit position.
407
The lower-limit sensor does not go ON within 12 seconds after the elevator motor operates in the
lowering direction.
408
The upper-limit sensor is OFF continuously for over 2 seconds during operation of the elevator
servo action to raise the feed tray.
1) Serviceman Call Errors (Pxx)