13 - 9
CZ180 / CV1860 Rev. 1.0
CHAPTER 13: PANEL MESSAGE
Error Type
P08 [Communication error with CI]
Description
P08-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Turn the power OFF and ON.
Error Point
Error Conditions
951
The file is not a correct RINC data.
Error Type
P12 [Master disposal area motor lock]
Description
P12-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset dis-
play
Press Reset Key.
Error Point
Error Conditions
301
Master compression motor lock when moving compression plate up.
302
The master compression HP sensor does not go OFF within 3 seconds after the master compres-
sion motor rotates in the reverse direction.
305
Master compression HP sensor does not go ON within 1 second after the master compression mo-
tor operates in the return direction.
306
Master compression HP sensor does not go OFF within 3 seconds after the master compression
motor operates in the compress direction.
309
Master-compression-motor encoder sensor count did not change as the master compression motor
activated in the compress direction and moved out from the home position.
313
The master compression HP sensor does not go ON even after 1 second after the master compres-
sion motor rotates in the compress direction.
316
Master-compression-motor encoder sensor count did not change within 10 milliseconds after the
master compression motor activated.
RISO Inc. Technical Services & Support
US.RISO.COM