13 - 10
CZ180 / CV1860 Rev. 1.0
CHAPTER 13: PANEL MESSAGE
Error Type
P13 [Cutter motor lock]
Description
P13-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Press Reset Key.
Error Point
Error Conditions
205
Master-positioning sensor is ON when the print drum rotates through the preset angle following
master cutting.
221
The cutter HP switch and cutter stop position switch are both ON at the same time.
222
Cutter HP switch does not go ON within 450 milliseconds after the cutter home positioning operation
started.
231
Cutter HP switch does not go OFF within 500 milliseconds after the cutter operation started from
the HP position.
232
Cutter stop position switch does not go ON even after 2 seconds after the cutting movement
started.
233
Cutter stop position switch does not go OFF even after 500 milliseconds after the cutter HP
movement started.
234
Cutter HP switch does not go ON even after 2 seconds from the cutter HP movement started.
Error Type
P17 [Solenoid counter not connected]
Description
P17-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Connect the solenoid counter.
Error Point
Error Conditions
020
Master counter (solenoid counter) is not connected.
021
Copy counter (solenoid counter )is not connected.
Error Type
P20 [Paper-ejection-section motor lock]
Description
P20-xxx
!!System Error!!
Press Reset Key
If Recovery has Failed, Call Service
To reset
display
Press Reset key
Error Point
Error Conditions
437
Paper-ejection encoder sensor status does not change within 10 milliseconds after the paper-
ejection motor is activated.
RISO Inc. Technical Services & Support