14 - 2
CZ180 / CV1860 Rev. 1.0
CHAPTER 14: TEST MODE
1. Operating Method
1) Launching the Normal Test Mode
To start Test Mode, switch ON the machine power while simultaneously pressing the left and right
keys of the vertical print positioning.
The firmware version number is displayed when the Test Mode is launched.
Press the Stop Key or Cancel Key to go into standby mode.
From the standby mode, enter the required test mode number and press Start Key to activate.
Press the Stop Key or Cancel Key to return back to the standby mode.
Enter next desired test mode number to continue using the test mode, or press the Reset Key for one
second to escape out from the Test Mode.
The Reset Key must be pressed (for 1 second) to escape out from the Test Mode only when the ma-
chine is in the standby mode of the test mode.
2) Launching the Protected Area Test Mode
Launch the machine into normal test mode and to the standby mode.
Enter the four digit password to go into the Protected Area Test Mode, which is
9874
, and press the
Start Key. The Protected Area Test Mode is launched.
Enter the desired protected area test mode number and press the Start Key to activate.
To escape out from the Protected Area Test Mode, press the Stop Key or Cancel Key and then press
the Cancel Key for one second. This will return the machine back to the normal machine operating
condition.
RISO Inc. Technical Services & Support
US.RISO.COM