14 - 8
CZ180 / CV1860 Rev. 1.0
CHAPTER 14: TEST MODE
0380
AF Horizontal Scan Position Adjust
Description
Adjusts the original horizontal scan position on the AF unit.
Setting
Range : -30 to +30 (-3.0mm to +3.0mm)
(+ is to the left )
Unit : 5 (0.5mm)
Default : 0 (0mm)
0381
AF Scan Start Position Adjust
Description Adjusts the original scanning start position on the AF unit (amount of top image omitted)
Setting
Range : -20 to +20 (-2.0mm to +2.0mm)
(+ omits more top image of the original and moves the printed image
up)
Unit : 1 (0.1mm)
Default: 0 (0mm)
0382
AF Scanning Speed Adjustment
Description
Adjusts the original scanning speed on the AF unit (Adjust the speed of AF Read Pulse
Motor)
Setting
Range : -100 to +100 (-10.0% to +10.0%)
( + elongates the image)
Unit : 1 (0.1%)
Default : 0 (0%)
Rough reference in changing the elongation or shrinkage by 1mm is:
A3=0.2%, B4=0.3%, A4=0.3%, Ledger=0.2%, Legal=0.3%
0386
Center dotted line
Description
Adds center dotted line on the prints during master-making or printout from linked printer.
(The dotted line is added only when the original is scanned on the AF unit.)
Make sure to return the parameter setting back to [ 0 ] after using setting [ 1 ] to make
the center line for an adjustment.
Otherwise the machine makes the center dotted line on
all printings made from AF scanning.
Setting
0: No center dotted line (default)
1: Adds center dotted line
RISO Inc. Technical Services & Support
US.RISO.COM