14 - 9
CZ180 / CV1860 Rev. 1.0
CHAPTER 14: TEST MODE
No.
Sensor switch check
Detection status
0400 Master-positioning sensor
Sensor light reflected (Master present) / No reflection ( No master)
0402 Master end sensor
Sensor light blocked (Master end seal detected)
0403 Cutter HP Switch
Switch pressed (Cutter at home position)
0404 Cutter stop position switch
Switch pressed (Cutter at end position)
0409 Master-making-unit safety SW
Switch pressed (Master-making unit upper cover is closed).
Other safety switches must be ON for this check.
0420 Master-disposal jam sensor
Sensor light is not blocked (Master is detected - jammed)
0421 Master-compression HP Sensor Sensor light blocked (Master compression plate at HP)
0422 Master disposal box FULL sensorSensor ON (Master disposal box FULL)
0423 Master-disposal BOX safety SW
Switch ON (Master-Disposal Box set in position).
Other safety switches must be ON for this check.
0425
Master-compression motor FG
sensor
Sensor light blocked (Encoder disc is detected)
0426 Master-removal motor FG sensorSensor light blocked (Encoder disc is detected)
No.
Motor, solenoid
Remarks
0462
Write pulse motor in feed
direction
Rotates in master feeding direction (clockwise direction)
0463
Write pulse motor in return
direction
Rotates in master returning direction (counter-clockwise)
0464
Load pulse motor in feed
direction
Rotates in master feeding direction (clockwise direction)
0466
Write pulse motor + Load pulse
motor in feed direction
Rotates both the Write & Load pulse motors in master feed direction
(clockwise direction)
0470
Master removal motor in feed
direction
Rotates in the direction to feed the removed master towards the master
disposal box (clockwise direction)
No.
Unit check
0480
Cutter motor 1 cycle motion
Performs one cutting motion.
0490
Master compression plate home positioning
Moves master compression plate to the home position.
0493
Master compression plate continuous movement
Repeats disposal compression action with interval of 3 seconds between the each.
0494
Cutter motor ON action (cut direction)
[This test mode is for checking the motor as one independent part. Disconnect the motor from the cutter unit
before activation.]
Rotates the cutter motor in the cut direction (maximum 10 seconds)
0495
Master compression motor ON action (cut direction)
[This test mode is for checking the motor as one independent part. Disconnect the motor from the master
disposal unit before activation.]
Rotates the master compression motor in the cut direction (maximum 10 seconds)
3) Master-making & Master-disposal Test Modes
RISO Inc. Technical Services & Support
US.RISO.COM