14 - 18
CZ180 / CV1860 Rev. 1.0
CHAPTER 14: TEST MODE
No.
Sensors, switches
Detection status
3100 Job separator tape jam sensor Jammed tape is detected
3101
Job separator tape detection
sensor
Tape is detected
3102 Job separator power switch
Power is supplied to the Job separator
3103 Job separator connection signal Job separator is connected
No.
Unit check
3140
Tape output
Outputs one tape.
(The stamping action by Test Mode No.3170 applies.)
No.
Data setting
3170
Stamping quantity
Description
Sets number of times the Stamper stamps per one tape cut.
(This test mode is active only for stamping action check by serviceman when using Test
Mode No.3140 to check tape output.) This test mode parameter setting is inactive in normal
machine usage.)
Setting
0: No stamping (default)
1: One stamping
2: Two stamping
3171
Activate or deactivate the tape jammed message
Description Activates or deactivates the Tape Jam message while using the Job Separator.
Setting
0: Does not indicate the jammed message on operation panel.
1: Indicates the jammed message on operation panel. (default)
7) Test Modes for the Optional Unit (Job Separator)
RISO Inc. Technical Services & Support
US.RISO.COM