Float Adjustment

 – Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water

depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing-nut. With the valve
functioning properly and the water level set at the proper level, you may install the valve cover. The water seal
groove between the frame and valve cover must be filled with liquid to create a protective seal from cold winter
air getting to the valve.

T.

Install Side Access Panel

 – Once all water line connections have been checked for leaks and electrical hook-

up is complete, the side access door may be installed.

U.

Children should be supervised to ensure that they do not play with the appliance – 

This appliance is not

intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of

experience and knowledge, unless they have been given supervision or instructions concerning use of the

appliance by a person responsible for their safety.

V.

Cleaning Your Fountain 

–  To clean your watering fountain you will need a good stiff bristled brush.

Remove the cover then brush the water seal groove to remove any build-up then brush the tank.  Remove the plug

that is located in the valve chamber area under the float to drain out the water and debris. You can shut off the

water with the shut-off valve located under the unit or by holding the float in the up position.  After the water and

debris has drained reinstall the plug and let the tank refill.  Now is a good time to readjust the float if needed.

Reinstall cover and you are done.

Ritchie Valves 

Ritchie valves come in various sizes and  pressure ratings  as shown below  -  green for high supply line 

pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of 

trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each 

fountain will only accommodate one size and configuration of valve. Your individual situations may require a 

change from the standard valve supplied with your fountain, see your Ritchie Dealer if this is needed. 

NOTE

:  

The red ½” valve is standard on the OmniFount 1, 2 & 2 SP and the green ¾” valve is standard 

on the OmniFount 3, 5 & 10.

 

1/2” 

Part #  GPM 

Pressure Range 

White  12574 

4.8 

Low, 5-40 psi.  

 (34-275 kPa) 

Red 

12575 

3.4 

Moderate, 40-60 psi.   (275-414 kPa) 

Green  13597  1.45 

High, 60-80 psi.   

  (414-552 kPa) 

3/4” 

Part #  GPM 

Pressure Range 

White  16697 

33 

Low, 5-40 psi  

 (34-275 kPa) 

Red 

11101 

20 

Moderate, 40-60 psi   (275-414 kPa) 

Green  15377  16.5 

High, 60-80 psi  

 (414-552 kPa) 

NOTE:  Maximum inlet water pressure for each valve is shown above.  If water pressure is extremely 

high, and if the valve does not shut off, a pressure-reducing valve may be needed.

 

OmniFount Series Instruction Manual

6

January 1, 2020

Summary of Contents for 16533

Page 1: ...fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before installing Ritchie Industries Inc 800 747 0222 www ritchiefount com Part 17835 January 1 2020 RitchieWaterers ...

Page 2: ...y line thoroughly before connection to fountain Water supplies with foreign material such as sand rust etc may require a filter to keep fountain valve working properly C Electric Supply It is generally most cost effective to run your electrical supply line at the same time you are trenching for your water supply WARNING ANY ELECTRICAL SERVICE MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED ELECTRI...

Page 3: ...the OmniFount 5 10 have 6 molded hold down pockets The use of 3 8 x 5 stainless steel expansion anchor bolts not included is recommended Anchor bolts are available from Ritchie in a two pack part 16555 Large diameter fender washers are included and should be used with anchor bolt to prevent damage to the plastic casing Remove the side access panel to prepare for the remainder of the installation p...

Page 4: ...cal codes A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For wiring connections see wiring diagram Make connections according to the wiring diagram below WARNING DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO THE WATERING FOUNTAIN WARNING THIS INSTALLATIO...

Page 5: ...NG DIAGRAM 240V SINGLE PHASE WARNING Check the nameplate for your unit Only connect 120VAC to a 120V Unit WARNING Check the nameplate for your unit Only connect 230 240VAC to a 240V Unit OmniFount Series Instruction Manual 4 January 1 2020 ...

Page 6: ...n was already made in step H for the Omni 3 5 O Seal the Base After the unit is completely installed apply a bead of caulking around the base of the fountain to ensure no wind enters through the base of the unit NOTE Sealing the bottom of the unit from cold air is an important aspect of the unit s thermal performance P Drain Plug Insert the drain plug firmly into the drain hole in the center of th...

Page 7: ... and debris You can shut off the water with the shut off valve located under the unit or by holding the float in the up position After the water and debris has drained reinstall the plug and let the tank refill Now is a good time to readjust the float if needed Reinstall cover and you are done Ritchie Valves Ritchie valves come in various sizes and pressure ratings as shown below green for high su...

Page 8: ...18147 Access Panel Hardware pkg 1 pkg 21 18633 Plug 3 Water Channel 2 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 18266 Frame Bolt nut wshr SS 3 pkg 1 pkg NS 16627 Omni 1 Accessory pkg 1 pkg 9 18655 Ritchie Decal 7 5 1 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 10 18628 Drain Plug 2 pkg 1 pkg NS 14866 Seal Foam 1 2 x3 4 x10 Roll 1 11 14150 Heater 120...

Page 9: ...6 18147 Access Panel Hardware pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 16627 Omni 2 Accessory pkg 1 pkg 8 18266 Frame Bolt nut wshr SS 3 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 9 18628 Drain Plug 2 pkg 1 pkg NS 14866 Seal Foam 1 2 x3 4 x10 Roll 1 10 14150 Heater 120V 125W 1 pkg 2 pkgs 11 18075 Drain Washer 6 pkg 1 pkg 12 11471 Drain Pipe with ...

Page 10: ... 1 6 18147 Access Panel Hardware pkg 1 pkg 21 18633 Plug 3 Water Channel 2 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 18266 Frame Bolt nut wshr SS 3 pkg 1 pkg NS 16627 Omni 2 Accessory pkg 1 pkg 9 18653 Ritchie Decal 12 1 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 10 18628 Drain Plug 2 pkg 1 pkg NS 14866 Seal Foam 1 2 x3 4 x10 Roll 1 11 14150 Heater...

Page 11: ...hannel 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 16554 Omni 3 Accessory pkg 1 pkg 8 18319 Frame Bolt Wshr SS 2 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 9 18095 Trough Screw Nut SS 2 pkg 1 pkg NS 14866 Seal Foam 1 2 x3 4 x10 Roll 1 10 18...

Page 12: ...hannel 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 16554 Omni 5 Accessory pkg 1 pkg 8 18319 Frame Bolt Wshr SS 2 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 9 18095 Trough Screw Nut SS 2 pkg 1 pkg NS 14866 Seal Foam 1 2 x3 4 x10 Roll 1 10 18...

Page 13: ... 1 pkg 20 18633 Plug 3 Water Channel 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 16554 Omni 10 Accessory pkg 1 pkg 8 18471 Frame Bolt Wshr SS 4 pkg 1 pkg NS 16523 Seal Foam 1 4 x3 4 x25 Roll 1 9 18095 Trough Screw Nut SS 2 pkg 4 pkgs NS 14866 Sea...

Page 14: ...at riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Valve won t stop dripping Check float adjustment Check for waterlogged float or float rubbing on side of valve compartment Check for excessive system water pressure Disassemble valve and check for sand...

Page 15: ... rights which vary from state to state All warranty claims must be processed through an Authorized Ritchie Dealer Distributor Proof of purchase is required This warranty is not transferable The period of warranty begins at original date of purchase as follows Poly Units Base top and ball closures 10 year limited against manufacturing defect 100 first five years then declining 20 per year for the r...

Reviews: