S.
Float Adjustment
– Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water
depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing-nut. With the valve
functioning properly and the water level set at the proper level, you may install the valve cover. The water seal
groove between the frame and valve cover must be filled with liquid to create a protective seal from cold winter
air getting to the valve.
T.
Install Side Access Panel
– Once all water line connections have been checked for leaks and electrical hook-
up is complete, the side access door may be installed.
U.
Children should be supervised to ensure that they do not play with the appliance –
This appliance is not
intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instructions concerning use of the
appliance by a person responsible for their safety.
V.
Cleaning Your Fountain
– To clean your watering fountain you will need a good stiff bristled brush.
Remove the cover then brush the water seal groove to remove any build-up then brush the tank. Remove the plug
that is located in the valve chamber area under the float to drain out the water and debris. You can shut off the
water with the shut-off valve located under the unit or by holding the float in the up position. After the water and
debris has drained reinstall the plug and let the tank refill. Now is a good time to readjust the float if needed.
Reinstall cover and you are done.
Ritchie Valves
Ritchie valves come in various sizes and pressure ratings as shown below - green for high supply line
pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of
trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each
fountain will only accommodate one size and configuration of valve. Your individual situations may require a
change from the standard valve supplied with your fountain, see your Ritchie Dealer if this is needed.
NOTE
:
The red ½” valve is standard on the OmniFount 1, 2 & 2 SP and the green ¾” valve is standard
on the OmniFount 3, 5 & 10.
1/2”
Part # GPM
Pressure Range
White 12574
4.8
Low, 5-40 psi.
(34-275 kPa)
Red
12575
3.4
Moderate, 40-60 psi. (275-414 kPa)
Green 13597 1.45
High, 60-80 psi.
(414-552 kPa)
3/4”
Part # GPM
Pressure Range
White 16697
33
Low, 5-40 psi
(34-275 kPa)
Red
11101
20
Moderate, 40-60 psi (275-414 kPa)
Green 15377 16.5
High, 60-80 psi
(414-552 kPa)
NOTE: Maximum inlet water pressure for each valve is shown above. If water pressure is extremely
high, and if the valve does not shut off, a pressure-reducing valve may be needed.