S. Install Side Access Panel
– Once all water line connections have been checked for leaks and electrical hook-
up is complete, the side access door may be installed.
T. Children should be supervised to ensure that they do not play with the appliance –
This appliance is not
intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance
by a person responsible for their safety.
U. Cleaning Your Fountain
– To clean your watering fountain you will need a good stiff bristled brush. Remove
the cover then brush the water seal groove to remove any build-up then brush the tank. Remove the plug that is
located in the valve chamber area under the float to drain out the water and debris. You can shut off the water with
the shut-off valve located under the unit or by holding the float in the up position. After the water and debris has
drained reinstall the plug and let the tank refill. Now is a good time to readjust the float if needed. Reinstall cover
and you are done.
Ritchie Valves
Ritchie valves come in various sizes and pressure ratings as shown below - green for high supply line pressure, red
for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts
valve choice. Although different pressure rated valves may be used in a fountain, each fountain will only
accommodate one size and configuration of valve. Your individual situations may require a change from the
standard valve supplied with your fountain, see your Ritchie Dealer if this is needed.
NOTE
:
The green ¾” valve is standard on the OmniFount 3, 5 & 10.
3/4”
Part #
GPM
Pressure Range
White
16697
33
Low, 5-40 psi
(34-275 kPa)
Red
11101
20
Moderate, 40-60 psi (275-414 kPa)
Green
15377
16.5
High, 60-80 psi
(414-552 kPa)
NOTE: Maximum inlet water pressure for each valve is shown above. If water pressure is extremely high,
and if the valve does not shut off, a pressure-reducing valve may be needed.
OmniFount Large Series Instruction Manual
5
August 13, 2022