background image

10

Pub. 1147 - Rev. 7 SEPTEMBER 2004

Mechanical Dock Leveler Hydraulic Conversion

WELDING PROCEDURES:
Ground welder to front frame angle
for welding strut base or missing
anchor loop. 

I n s u r e   t h a t   t h e   c o n c r e t e   i s   a t
l e a s t   4 ”   d e e p   a n d   i n   g o o d  
c o n d i t i o n .  

Never weld on leveler when the electrical
components are connected to the main
control box and the power to the box is
on. 

D o   n o t   a t t e m p t   t o   c u t   a w a y  
hardware that is under a load. 

Lockout / Tagout procedures

When working with electrical or
electronic controls, make sure that
t h e   p o w e r   s o u r c e   h a s   b e e n   l o c k e d
out and tagged according to OSHA
regulations 1910.147 and approved
e l e c t r i c a l   c o d e s .  

Barricade work area

Post safety warnings and barricade
work area at dock level and ground
level to prevent unauthorized use
of the dock position while service
work is being performed.  Support
leveler platform safely while 
performing work. 

Safe-T-Strut Installation

If this strut is improperly installed
serious injury or death may result.
The Safe-T-Strut should only be
installed by qualified personnel.
For help call 1-800-456-0600. 

CAUTION

WARNING

WARNING

WARNING

WARNING

WARNING

CAUTION

Summary of Contents for Mechanical Dock Leveler Hydraulic Conversion

Page 1: ...Mechanical Dock Leveler Hydraulic Conversion Installation Owner s Manual Rite Hite Print Shop Pub 1147 Rev 7 SEPTEMBER 2004 AFTERMARKET CORPORATION...

Page 2: ...to lock in movable rear hinge if necessary 6 Electrical Cord Conduit Tools Needed 1 Steel hawg magnetic drill or similar drill 2 1 25 bit for magnetic drill 3 Hammer drill 4 Welder Grinder Torch 5 Mi...

Page 3: ...ation does not recommend any particular lockout device but recommends the utilization of an OSHA approved device refer to OSHA regulation 1910 147 RITE HITE Corporation also recommends the review and...

Page 4: ...orm Lip Cylinder Lug Bracket Ramp Clevis Platform Rear Ramp Hinge Pin Lip Lug Lip Keepers Front Bracket Pit Floor MECHANICAL COMPONENTS Subframe Rear Front Rear ELECTRICAL COMPONENTS Rear HYDRAULIC CO...

Page 5: ...Hydraulic oil can be added to the system by removing the cap and pouring oil into the reservoir NOTE When adding oil use only MIL H 5606 SAFETY STOP SYSTEM The hydraulic system has an emergency flow c...

Page 6: ...oncrete in the position for the unit to be capable of conversion PLATFORM CENTERLINE OBSTRUCTIONS If the platform of the leveler has any structural reinforcements or supports between the center string...

Page 7: ...00 lbs WARNING Always use safe work habits This kit includes a maintenance strut Always use this maintenance strut when working under the leveler WARNING Be sure to follow these Caution notes when ins...

Page 8: ...8 Pub 1147 Rev 7 SEPTEMBER 2004 Mechanical Dock Leveler Hydraulic Conversion ELECTRICAL INSTALLATION DETAILS FIGURE 2...

Page 9: ...late Insure the structural integrity of the leveler Make sure the leveler will have at least five more years of useful life after the conversion is complete IMPORTANT Make sure rear hinge of leveler i...

Page 10: ...ng with electrical or electronic controls make sure that the power source has been locked out and tagged according to OSHA regulations 1910 147 and approved electrical codes Barricade work area Post s...

Page 11: ...the method for installing the base depending on the type of front sub frame and the support that will be needed to transfer all loading directly to the pit floor concrete IMPORTANT OBSERVE ALL SAFETY...

Page 12: ...s lip stop bolts etc See Figure 4 2 Position the strut base so the hole is parallel to the front of the leveler and the chamfered edge is against the front frame 3 Shim under the front sub frame at th...

Page 13: ...eight 5 Locate the strut base with extension within 12 of the centerline of the leveler so that it does not interfere with the board operation Before beginning installation check for potential clearan...

Page 14: ...e within 12 of the centerline of the leveler so that it does not interfere with the board operation Before beginning installation check for potential clearance problems with lip lugs header bridge bar...

Page 15: ...er frame near the strut base 4 Connect the free end of the strut chain to the frame anchor loop See Figure 10 FIGURE 8 LIP HOLE LOCATION FIGURE 9 STRUT CUT TO LENGTH LIP INSTRUCTIONS 1 Locate and dril...

Page 16: ...place to the stringers The bracket should open toward the front of the leveler Insure the bracket is square to the leveler deck so the hydraulic cylinder stays on the center line of the leveler 4 Cut...

Page 17: ...nge to position the pit floor bracket See Figure 12 Draw a line on the pit floor parallel to the hinge at this position This dimension is critical to make sure the ramp cylinder does not bottom out on...

Page 18: ...fuse into adapter of ramp cylinder Fasten securely 5 Install hoses between the pump and the ramp and lip cylinders The small hose should be connected to the lip cylinder and the larger hose should get...

Page 19: ...s base Leave bolts in place 5 Paint all brackets and welds to control rust PUMP ADJUSTMENTS 1 Run leveler and adjust properly a Adjust shuttle valve so that leveler platform lowers from top to bottom...

Page 20: ...20 Pub 1147 Rev 7 SEPTEMBER 2004 Mechanical Dock Leveler Hydraulic Conversion FIGURE 14 QUICK CLEAN FRAME MODIFICATIONS...

Page 21: ...Pub 1147 Rev 7 SEPTEMBER 2004 21 Mechanical Dock Leveler Hydraulic Conversion LIP KEEPER SUPPORT FOR LEVELERS WITH INADEQUATE FRONT SUSPENSION FIGURE 15...

Page 22: ...tch activates the power unit during the automatic return to dock process raising the leveler while the lip falls to the fully pendant position As the lip falls to the pendant position the rotary cam m...

Page 23: ...Rev 7 SEPTEMBER 2004 23 Mechanical Dock Leveler Hydraulic Conversion Limit Switch Cam Block Top Collar Bottom Collar Front Header 1 16 Between Center of Switch and Edge of Cam Block FIGURE 17B ARTD AD...

Page 24: ...termittent Duty Thermally Protected With Automatic Reset L2 1L1 Optional Raise Raise ARTD SOLID STATE LEVELER CONTROL MODULE Door Jumper Is Standard Remove Jumper If Optional Overhead Door ITC ITL Is...

Page 25: ...e Typ 2 Places Transformer Secondary Fusing 0 5 Amp 250V 3 AG Slow Blow Optional Door Interlock Limit Switch By Others IMPORTANT Motor Lead Connections Wire Termination Wire Nut Or Equal Device 50 VA...

Page 26: ...0 5 Amp 250V 3 AG Slow Blow Optional Door Interlock Limit Switch By Others LS1 N O H C Restrictor Sw LS2 N O ARTD Limit Sw Motor 1 HP 3450 RPM 380V 3 Ph 50 Hz Use Min 12 Gage 60 75 C Copper Wire 100...

Page 27: ...5 Amp 250V 3 AG Slow Blow Optional Door Interlock Limit Switch By Others LS1 N O H C Restrictor Sw LS2 N O ARTD Limit Sw Motor 1 HP 3450 RPM 480V 3 Ph 50 60 Hz Use Min 12 Gage 60 75 C Copper Wire 100...

Page 28: ...5 Amp 250V MDL Dual Element Type Optional Door Interlock Limit Switch By Others LS1 N O H C Restrictor Sw LS2 N O ARTD Limit Sw Motor 1 HP 3450 RPM 575V 3 Ph 50 60 Hz Motor Lead Connections Wire Term...

Page 29: ...ltage Amps 120 Volt 1 Phase 110 14 115 7 to 14 208 Volt 1 Phase 200 7 205 4 to 7 230 Volt 3 Phase 220 5 5 220 3 8 to 5 5 460 Volt 3 Phase 440 3 2 440 1 9 to 3 2 Motor Single Phase Single Phase Power U...

Page 30: ...leveler DO NOT operate leveler until truck trailer is parked against the dock bumpers and the truck trailer has been secured NEVER attempt to lift the lip or hold the lip out by hand Serious personal...

Page 31: ...lip is on the truck trailer and the truck pulls out the leveler will move to its lowest position and the lip will begin to lower As the lip drops toward the pendant position the ARTD system automatic...

Page 32: ...r and the truck pulls out the leveler will move to its lowest position and the lip will begin to lower As the lip drops toward the pendant position the ARTD system automatically returns the leveler to...

Page 33: ...base 3 Shut off power at the disconnect switch and lockout tagout according to OSHA regulations 4 Remove all debris from the leveler and pit Be sure the hinge section of the lip and platform is clean...

Page 34: ...s Locknut Cap Adjustment Screw Shuttle Valve Body Locknut Seal O Rings Cap Sequence Valve Adjustment Screw Viewed From Tank End System Relief Valve 1 Leveler must be adjusted to lower from full raised...

Page 35: ...turning valve body or adjustment screw 5 Reinstall O ring and protective cap and tighten cap 6 Re test the unit several times to verify the setting 7 If the lip begins to extend at any time before the...

Page 36: ...3 1 2 x 16 S A 5 And 6 Long 3 1 2 GPM 8 And 10 Long 5 GPM Lip Cylinder 1 1 2 x 6 S A Suctin Filter M Motor 3450 RPM Pump Check Valve Orifice Plug Orifice Plug Pilot To Open Check Valve Pilot To Close...

Page 37: ...Pub 1147 Rev 7 SEPTEMBER 2004 37 Mechanical Dock Leveler Hydraulic Conversion OPTIONAL EQUIPMENT DOOR INTERLOCK FIGURE 38 FIGURE 39...

Page 38: ...fitting the bottom of the SAFE T STRUTTM base When working with electrical or electronic controls make sure that the power source has been locked out and tagged according to OSHA regulations and appr...

Page 39: ...t all wires are correctly and solidly connected in the control box motor junction box and pit wall junction box g The overhead door interconnect g With overhead door ITC Verify has failed that limit s...

Page 40: ...ARTD cam power is turned on damaged b The ARTD system has failed b Verify that ARTD and restrictor limit switches are functional Type 2 Control Box Verify that the limit switches are wired to terminal...

Page 41: ...s fully or partially extended a Debris on lip hinge a Remove dirt debris and corrosion from the lip hinge spools b Lack of lubrication b Without grease fittings Lubricate the hinge spools with SAE30 o...

Page 42: ...lowly a Weight on top of platform a Remove weight from platform b Hydraulic fluid level is low b Check oil level in tank Refill if there is less than 3 1 2 of oil in the tank when the unit is held ope...

Page 43: ...ot applicable condition Type 2 Control Box Push RESET button to clear faults c There is a faulty wiring connection c Verify that all wires are correctly and solidly connected in the control box motor...

Page 44: ...e out fault b The pushbutton and or contact block b Type 2 Control Box Replace does not function properly or is stuck pushbutton and or contact block c The ARTD system has failed c Verify that ARTD an...

Page 45: ...JIC M 6728 6728 5 1 FTG ELB 90 4 SAE M 4 JIC M 16920 16920 16920 16920 6 1 FTG ELB 90 6 SAE M 6 JIC M 55267 55267 55267 55267 7 1 FTG ELB 45 4 JIC SWF 4 SAE M 100363 100363 100363 100363 8 1 FTG ELB...

Page 46: ...46 Pub 1147 Rev 7 SEPTEMBER 2004 Mechanical Dock Leveler Hydraulic Conversion ARTD ASSEMBLY...

Page 47: ...102640 11 1 Limit Switch Restrictor 100135 12 2 Screw Round Head 8 32 x 1 3 4 lg 100136 13 2 Washer External Tooth 8 51760 14 4 Washer Flat 8 51736 15 2 Nut 8 32 51538 16 2 Shaft Collar 68163 17 2 Fla...

Page 48: ...103163 2 1 Enclosure 65849 3 1 Switch Plunger OP 25A 125 250V AC 17687 4 1 Armored Pushbutton Boot 17688 5 2 Wire Term Ring Type 12 Wire 8 SCR 17690 6 1 Wire Marker 1L1 55821 7 1 Wire Marker T1 55535...

Page 49: ...HMS 8 32 x 1 1 2 Lg ZP 58181 6 2 Washer Ext Tooth 8 ZP 51839 7 1 Ground Lug and Sticker 55902 8 1 Pushbutton Black IEC 65887 9 2 Contact Block N O IEC 65890 10 1 Corrosion Retard Pad 55561 11 1 Drawin...

Page 50: ...2 100222 100222 100222 7 1 Terminal Block 16848 16848 16848 16848 8 1 Contactor 65911 65911 65911 65911 9 1 Overload Relay 65912 65912 65912 65912 10 1 Corrosion Retard Pad 55561 55561 55561 55561 11...

Page 51: ...0 5 1 Ground Lug and Sticker 55902 55902 55902 55902 6 2 Panel Control Box 100222 100222 100222 100222 7 1 Terminal Block 114 369 114 369 114 369 114 369 8 1 Contactor 65911 65911 65911 65911 9 1 Over...

Page 52: ...52 Pub 1147 Rev 7 SEPTEMBER 2004 Mechanical Dock Leveler Hydraulic Conversion...

Page 53: ...rut Kit 1 1 103967 Safe T Strut 63 long 1 2 51100 Anchor Loop 25 wire dia 1 3 16182 Chain assembly 1 4 59387 Base 4 25 Safe T Strut 1 5 103349 Extension Base 1 6 103495 Competitive Base support angle...

Page 54: ...54 Pub 1147 Rev 7 SEPTEMBER 2004 Mechanical Dock Leveler Hydraulic Conversion MECHANICAL PARTS 8 9 10A 2 3 4 1 11 6 7 5 10B...

Page 55: ...4 590 3 1 Toe Guard 8 Leveler RH 1707 526 4 1 Toe Guard 8 Leveler LH 1708 5 2 Lip Keepers Hydraulic 2175 669 6 1 Toe Guard 10 Leveler RH 1727 7 1 Clevis Pit Floor with Base 18241 8 1 Lip Cylinder Base...

Page 56: ...this warranty RITE HITECorporation will remedy such defects by repairing or replacing any defective equipment or parts bearing all of the costs for parts labor and transportation This shall be the ex...

Reviews: