TROLLEYS
1.
Locate the left and right hand trolley assemblies. Make
sure the trolley assembly has the wheels on the inside of
the sideframe and towards the back wall.
2.
Verify chain and cable are connected to the trolley,
Figure 18.
NOTE:
Covers must be installed with a 3/4" gap at the
curtain edge for proper trolley operation,
Figure 17.
INTERNAL SENSING SYSTEM CABLES
1.
Make sure to route the wire from the non-drive sideframe
thru the conduit of the header channel before putting on
the front cover,
Figure 19.
2.
Connect the wires from the drive sideframe and header to
the control box cable.
3.
Be sure not to pinch the wires as the header channel is
installed, also be sure to have wires down in the
sideframe so the trolley does not catch on them.
PHOTOEYE INSTALLATION
1.
Locate the Thru-Beam photoeye assembly in the drive
sideframe assembly,
Figure 20.
Located on the back end of
the photoeye assembly are three LEDs and one switch.
2.
The yellow “Power ON” LED should be on when the door
power is turned on.
3.
The “Light/ Dark” operate switch has been preset in the
“Light” operate position.
4.
The red and green LED’s will be on when the photoeye
receiver and the source are lined up correctly. If the red
and green LED’s are OFF, either the beam is blocked or
the photoeye is out of alignment. Adjustment using the
screws on the sideframe assembly beneath the photoeye,
Figure 20.
The two top screws allow for horizontal
adjustment and the single bottom screw adjusts vertical
alignment. Rotate the screw until the LED’s turn ON. If
after three turns the red and green LED’s do not turn on,
reverse direction.
After the red and green LED’s turn ON, continue to turn
the adjustment screw in the same direction, counting the
turns. Note when the LED’s turn OFF.
Divide the number of turns in half and reverse the turning
direction that number of turns to center the light beam.
Follow the same steps for the vertical adjustment until the
light beam is centered on the reflector.
Note:
This photoeye is for reversing only, not remote
activation. Photoeye should be mounted at an
elevation of 24" from the floor (pre-drilled holes on
both sideframes). Disconnect power before
installing external mounted photoeyes.
EXTERNAL PHOTOEYE INSTALLATION
1.
Locate the thru-beam photoeye components
(source, receiver, and mounting brackets).
2.
Install the source photoeye on the non-drive side
sideframe. Install the photoeye receiver on the drive side,
Figures 22 & 23.
3.
Insert the photoeye cable through the side of the
sideframe at the bottom and connect the cables together
at the connectors in the sideframe.
4.
With the power on, adjust the thru-beam photoeye by
loosening the two mounting bracket screws and rotating
the bracket and photoeye assembly until the red LED
turns on.
5.
Cable must be out of the inserts path.
Pub. No. 8000CLB FEBRUARY 2004
11
PROTECDOR® CL Model 8000CL
PHOTOEYE ADJUSTMENTS
The PROTECDOR CLEAN will not operate until
both the internal and external photoeye s have
been installed and aligned.
IMPORTANT!!!
FIGURE 22
FIGURE 20
Thru-Beam Photoeye
Assembly
Horizontal Adjustment
Vertical Adjustment
Drive Sideframe
Source