7
Green
Red
Got the answer
Send test message
8.9.
If an additional alarm wire loop is used, insert the ribbon cable and connect it to
the XT1.
8.10.
Put corresponding wires in slots and secure the enclosure base on the surface.
An enclosure tear-off tamper is installed by default.
8.11.
Switch the device to the standby mode (see Paragraph 5).
8.12.
Verify the signal path for alarm signals of the sensor, tamper, and, if necessary,
additional alarm wire loop by referring to LED indicators.
8.13.
Install the mating piece (magnet) not further than 10 mm away from the SA1 reed
relay. If necessary, use backing plates.
8.14.
The device is ready for operation.
9.
Hardware Reset to Factory Settings
Remove the battery from its holder, install the JMP1+JMP3 jumpers, and place the
battery back. This procedure is shown in the diagram:
t
5 times
The device reset settings
Red
The settings have been reset
to factory settings
The radio signal strength between the device and the control panel is
determined by the level of signal attenuation, which can be seen in the radio
channel security and control panel configuration software, page Radio Device
Map. For more information please refer to the control panel user manual.