6.2.
Error Codes and their
Descriptions
Code Descriptions
Er05
Battery weak or faulty
Er06
Output short-circuited
Er07
EPO mode
Er11
UPS over-temperature
Er12
Inverter overload
Er14
Fans out of order
Er18
EEPROM's data error
Er24
Utility Low (<170V) &
Battery Disconnect
Er28
Bypass overload
Note!
Does the PMC12 show an Error
Code that is not described in the
above table please contact the
Rittal Service.
6.3. Maintenance
Clean the dust from the ventilation openings
and intakes on the rear panel.
1. Turn off the UPS and wipe the casing with a
damp cloth.
2. Periodically unplug the power cord of the
UPS from the wall receptacle to test the
condition batteries. The period should be
determined by the user according to his
requirements as well as surroundings.
3. Be sure you have already saved your appli-
cation before you proceed the battery dis-
charging capability test.
7. Bundle Software Installation
7.1. Hardware
Installation
1. Connect the male connector of RS232/USB
cable to the UPS communication port.
2.
Connect the female connector of the
RS232/USB cable to a dedicated RS232 port
of the Computer.
3. For optional interface cards, please refer to
Chapter 8 for more details.
7.2. Software
Installation
Please visit our website
www.rimatrix5.com
and
for download from UPS software
www.rimatrix5.com/dl_power.htm
.
EP
O
G
DC
3
6
V
AC
O
U
T
P
U
T
2
1