background image

 

 

4

 

Transportation and

 handling

 

 

PSM overvoltage protection 

 

 EN 

4

 

Transportation and handling 

 

4.1

 

Transport 

The unit is delivered in a carton. 
 

 

Note! 

After unpacking, the packaging 
materials must be disposed of 
in an environmentally friendly 
way. They can consist of the 
following materials: 
Polyethylene film (PE film), 
cardboard. 

 

4.2

 

Unpacking 

 

Remove the unit's packaging materials. 

 

 

Note! 

After unpacking, the packaging 
materials must be disposed of 
in an environmentally friendly 
way. They can consist of the 
following materials: 
Polyethylene film (PE film), 
cardboard. 

 

 

Check the unit for any damage that has 
occurred during transport. 
 

 

Note! 

Damage and other faults, e.g. 
incomplete delivery, should 
immediately be reported to the 
shipping company and to Rittal 
GmbH & Co. KG in writing. 

 

 

Remove the unit from the packaging. 

 

5

 

Installation and siting 

5.1

 

Installation site requirements 

To ensure the correct function of the unit, the 
conditions for the installation site of the unit 
specified in section 6 "Technical specifications" 
must be observed. 
 

Electromagnetic interference 

 

Interfering electrical installations (high 
frequency) should be avoided. 

 

5.2

 

Installation 

The installation is made in accordance with the 
plug-and-play principle. 
The preassembled plug must be inserted in the 
appropriate socket of the PSM busbar. The 
connection to the infeed is made using the cable 
DK 7856.025 (available as accessory) or the 
connection plug included with the PSM busbar. 
 
 

 

 

Caution!

Rittal recommends the use of the pre-
assembled connection cables 
available as accessory. 
Ensure the correct positioning of the 
connection plug when making the 
connection! 
There is the danger of electrical shock 
and damage to the connected 
consumers in case of incorrect 
connection. 
The connection plugs that accompany 
the PSM busbars may only be 
installed by trained electricians! 

 
 

Summary of Contents for DK 7856.170

Page 1: ...Power System Modul Overvoltage protection DK 7856 170 Assembly and operating instructions ...

Page 2: ...description 4 3 1 Function 4 3 2 Requirement class 4 3 3 Proper use foreseeable misuse 4 4 Transportation and handling 5 4 1 Transport 5 4 2 Unpacking 5 5 Installation and siting 5 5 1 Installation site requirements 5 5 2 Installation 5 6 Technical specifications 6 7 Accessories 6 8 Customer service addresses 6 ...

Page 3: ...e available and on hand for the operating and maintenance personnel 1 3 Symbols in these operating instructions The following symbols are used in this documentation Note Useful information and special features Caution A dangerous situation for which the failure to comply with this note can cause minor injuries or machine damage 1 4 Other applicable documents Installation guide and short operating ...

Page 4: ... values stated in the technical specifications may not be exceeded under any circumstances In particular this applies to the specified ambient temperature range and IP degree of protection The PSM overvoltage protection must not be opened The unit does not contain any parts that need servicing The operation of the system in direct contact with water aggressive materials or in flammable gases and v...

Page 5: ... as possible 3 2 Requirement class The overvoltage protection is designed for requirement class D portable use on power sockets 3 3 Proper use foreseeable misuse The PSM overvoltage protection is used to protect against overvoltage on all three phases The overvoltage protection is provided for the overvoltage category ll in accordance with DIN VDE 0110 Part 1 It is designed for operation in data c...

Page 6: ...tion and siting 5 1 Installation site requirements To ensure the correct function of the unit the conditions for the installation site of the unit specified in section 6 Technical specifications must be observed Electromagnetic interference Interfering electrical installations high frequency should be avoided 5 2 Installation The installation is made in accordance with the plug and play principle ...

Page 7: ...cessories The accessories programme includes a connection cable to connect the PSM overvoltage protection to the power supply A detailed listing of the complete accessories programme is available at the Internet address specified in section 8 Customer service addresses Accessories Model No 3 phase connection cable with CEE plugs IEC 60 309 length 3 m 7856 025 Tab 2 Accessories 8 Customer service a...

Page 8: ...tion n Climate Control n IT Infrastructure n Software Services RITTAL GmbH Co KG Postfach 1662 D 35726 Herborn Phone 49 0 2772 505 0 Fax 49 0 2772 505 2319 E mail info rittal de www rittal com 1 Aufl 02 2013 Zeichn Nr A3102907IT74 ...

Page 9: ......

Reviews: