Technical Specifications 10
74
Switched Power Distribution Unit
EN
To reset to factory defaults, except network
settings
From the HTML interface
On the Restart page in the Tools section of the
HTML interface, select Restart and reset to fac-
tory defaults, except network from the drop-
down menu and press Apply.
From the command line
At the Switched PDU: prompt, type restart fac-
tory keepnet and press Enter.
9.2 Uploading Firmware
You may upload new versions of firmware using
File Transfer Protocol (FTP). This allows access
to new firmware releases for firmware improve-
ments and new features additions.
Note!
To begin an FTP upload session, you
must first configure the FTP Host ad-
dress, username/password, filename
and filepath.
You may initiate an FTP upload session by issu-
ing a command or from the HTML interface.
Upon initiating an FTP upload session, the unit
will restart and upload the firmware file specified
with the FTP Filename command from the previ-
ously configured FTP Host.
You must have administrator-level privileges to
initiate an upload.
To initiate an FTP upload session from the
HTML interface
On the Restart page in the Tools section of the
HTML interface, select Restart and upload
firmware via FTP from the drop-down menu and
press Apply.
To initiate an FTP upload session from the
command line
To initiate an FTP firmware upload session:
At the Switched PDU: prompt, type restart
ftpload and press Enter.
10 Technical Specifications
Switched PDU
Material
Sheet steel
Environment
Temperature
0 - +40 °C
+32 - +104 °F
Storage temperaturer
-40 - +85 °C
-40 - +185 °F
Humidity
10 - 90 % RH, not con-
densing
Tab. 4
Physical data
10.1 Technical Data
DK 7856
.530
.540
.550
Height
in mm
1260
1755
1270
Width
in mm
45
45
90
Depth
in mm
57
57
57
Weight
in kg
4,6
8,7
8,0
Supply-
Voltage
230V
400V
230V
Frequency
(in Hz)
50/60
50/60
50/60
Power Supply
1 x 32A
3 x 32A
2 x 32A
Connection
Plug
(1-phase)
.
-
.
(2x)
Plug
(3-phase)
-
.
-
Slots
C13
2 x 8
3 x 8
2 x 16
C19
-
-
-
Tab. 5
Technical data