5 Setting up the machine
Ritta l electrical crimping machine R8 E
We reserve the right to make technical m odifications.
15
EN
5.4.2
Insulation stripping stage setting
Required tool:
–
Allen key size 4
The insulation stripping stage / conductor cross-section is shown in the touch dis-
play.
◼
Turning clockwise increases the cross-section.
Fig. 9:
Insulation stripping stage setting
5.5
Replacing the belt roll
◼
Open the twist lock.
◼
Swivel the flap to the side.
◼
Press the transport pin upwards completely (see fig. 10, item 1) and remove the
wire end ferrule belt (see fig. 10, item 2) from the magazine.
Continue in accordance with section 5.3 "Inserting the belt roll".
Fig. 10:
Replacing the belt roll
5.6
Conductor insertion / conductor cutting
Note:
–
The cable must be cut straight and must not have any kinks or
bends.
–
Push the cable through the insertion funnel into the contact.
40 mm
Correct
Incorrect
Correct
Inclined
cut
–
+
1