background image

12

© 2006, Elektro-Automatik GmbH & Co. KG 

Irrtümer und Änderungen vorbehalten

EN

Installation Guide

33130328

Date: 01-05-2015

Description 

Wiring scheme of cabinet

Blatt

2 von 3

E

A

EA - Elektro Automatik

4x EL9080-600  42 HE

Bearb. :

Gez. :

Datum

Name

CAD System Microsoft Visio

Artikel Nr. : 33130328

Dateiname :

Gepr. :

31.10.14       H.Füllgrabe

Datum

Name

Geändert

33130328_VP-AC_01.vsd

31.10.14       H.Füllgrabe

31.10.14       H.Füllgrabe

F1

16A

L1

PE

N

L1

N

PE

L1

N

PE

L1

N

PE

L1

N

PE

1

58

1

58

+

-

+

-

+

-

+

-

1

3

X1

3

3

3

3

Mains supply

E-load 1

Master

E-load 2

Slave

E-load 4

Slave

E-load 3

Slave

Analog

interface

Analog

interface

Analog

interface

Analog

interface

Control bus

 (Sub-D 15 pole)

see separate

wiring scheme

Pos. DC terminal

78171485

Neg. DC terminal

78171485

All DC output cables 95mm²

Art. No.: 72393007

2x pcs. per unit, parallel for + and -

Summary of Contents for TS8 42U

Page 1: ...Installationsanleitung Installation Guide Schrank Cabinet EL Rack 42U 33 130 328 ...

Page 2: ......

Page 3: ...ster Slave System zu erhalten Das oberste Gerät ist dabei der Master der anderen Die Gerät sind dement sprechend markiert Solange die Verdrahtung an den analogen Schnittstellen gesteckt ist sind die Slave Geräte in ständiger Fernsteuerung und nur das Master Gerät kann normal bedient oder über eine digitale Schnittstelle ferngesteuert werden Bei Bedarf z B bei Entfernen eines Slave Gerätes zwecks R...

Page 4: ...er digitaler Schnittstelle Sobald der DC Eingang des Masters eingeschaltet wird nimmt der MS Verbund Leistung auf Jedes Gerät auch der Master zeigt auf seiner Anzeige nur die eigenen Werte es findet keine Summenbildung und anzeige statt Daher müssen die Werte von Strom und Leistung immer auf die Anzahl Geräte umgerechnet werden Zum Beispiel wenn Sie alle vier Geräte im MS benutzen und 100 A setzen...

Page 5: ...5 DE Datum 05 01 2015 Installationsanleitung 33130328 Beschreibung Ansichten Vorderseite Rückseite ...

Page 6: ... 31 10 14 H Füllgrabe Datum Name Geändert 33130328_VP AC_01 vsd 31 10 14 H Füllgrabe 31 10 14 H Füllgrabe F1 16A L1 PE N L1 N PE L1 N PE L1 N PE L1 N PE 1 5 8 1 5 8 1 3 X1 3 3 3 3 Mains supply E load 1 Master E load 2 Slave E load 4 Slave E load 3 Slave Analog interface Analog interface Analog interface Analog interface Control bus Sub D 15 pole see separate wiring scheme Pos DC terminal 78171485 ...

Page 7: ...ame CAD System Microsoft Visio Artikel Nr 33 130 328 Dateiname 33130328_VP Steuerleitung_01 vsd Gepr 31 10 14 Füllgrabe 31 10 14 Füllgrabe Datum Name Geändert 31 10 14 H Füllgrabe 15pol Analogschnittstelle Unterste Last Slave 3 1 8 9 15 15pol Analogschnittstelle Mittlere Lasten Slaves 1 2 1 8 9 15 AGND 15pol Analogschnittstelle Oberste Last Master CSEL DGND 1 8 9 15 grau lila orange AGND CSEL DGND...

Page 8: ...Automatik 4x EL9080 600 42 HE Bearb Gez Datum Name CAD System Microsoft Visio Artikel Nr 33130328 Dateiname Gepr 31 10 14 H Füllgrabe Datum Name Geändert 33130328_VP AC_01 vsd 31 10 14 H Füllgrabe 31 10 14 H Füllgrabe L1 L2 L3 N PE Unit 1 Master EL 9080 600 HP 9 U 6 U Unit 2 Slave 1 EL 9080 600 HP Unit 3 Slave 2 EL 9080 600 HP 9 U 9 U Unit 4 Slave 3 EL 9080 600 HP FP 6 HE 9 U ...

Page 9: ...to have a current driven mas ter slave system The topmost unit is defined as master unit All units are labelled on the front side The slave units are in permanent remote control indicated as External mode in display as long as the master slave wiring on the analog interface is plugged In case you need to access a unit separately or take over remote control via digital interface it is sufficient to...

Page 10: ...face When switching the DC input of the master on all units start draw ing current from the source so the units act as one big system However the master only show set values and actuals of itself so the total current or power intake has to be translated every time For example if you use all four units in the MS and you want to set 100A the master has to be set to I 100A number of units 25A in orde...

Page 11: ...11 EN Date 01 05 2015 Installation Guide 33130328 Views Front Rear Description ...

Page 12: ... 31 10 14 H Füllgrabe Datum Name Geändert 33130328_VP AC_01 vsd 31 10 14 H Füllgrabe 31 10 14 H Füllgrabe F1 16A L1 PE N L1 N PE L1 N PE L1 N PE L1 N PE 1 5 8 1 5 8 1 3 X1 3 3 3 3 Mains supply E load 1 Master E load 2 Slave E load 4 Slave E load 3 Slave Analog interface Analog interface Analog interface Analog interface Control bus Sub D 15 pole see separate wiring scheme Pos DC terminal 78171485 ...

Page 13: ... Artikel Nr 33 130 328 Dateiname 33130328_VP Steuerleitung_01 vsd Gepr 31 10 14 Füllgrabe 31 10 14 Füllgrabe Datum Name Geändert 31 10 14 H Füllgrabe 15 pole analog interface lower unit Slave 3 1 8 9 15 15 pole analog interface center units Slaves 1 2 1 8 9 15 AGND 15 pole analog interface upper unit Master CSEL DGND 1 8 9 15 grey lilac orange AGND CSEL DGND AGND CSEL DGND Wiring scheme of analog ...

Page 14: ...E Bearb Gez Datum Name CAD System Microsoft Visio Artikel Nr 33130328 Dateiname Gepr 31 10 14 H Füllgrabe Datum Name Geändert 33130328_VP AC_01 vsd 31 10 14 H Füllgrabe 31 10 14 H Füllgrabe L1 L2 L3 N PE Unit 1 Master EL 9080 600 HP 9 U 6 U Unit 2 Slave 1 EL 9080 600 HP Unit 3 Slave 2 EL 9080 600 HP 9 U 9 U Unit 4 Slave 3 EL 9080 600 HP FP 6 HE 9 U Description Unit allocation ...

Page 15: ......

Page 16: ...EA Elektro Automatik GmbH Co KG Entwicklung Produktion Vertrieb Helmholtzstraße 31 33 41747 Viersen Germany Telefon 02162 37 85 0 Telefax 02162 16 230 ea1974 elektroautomatik de www elektroautomatik de ...

Reviews: