Cascade Installation Guide
50
Verifying Remote Management Module access
Verify that the RMM can be accessed as follows:
1.
Point your browser to the IP address that you specified for the RMM on
the Sensor
Setup
page during the
Configuration
task. For example,
https://192.168.1.150
This displays the RMM login page.
2.
Log in to the
admin
account with the default password
password
(unless
you arranged for the system to be shipped with a different password).
3.
While logged in to the RMM, you can change the default RMM password
and define additional RMM user accounts.
A successful login verifies accessibility to the remote management module.
Exiting the installation process
After verifying that the Sensor is receiving and reporting traffic data and its
remote management module is accessible over the network, ensure that the
responsible person has the IP address, login name, and password of the Sensor
and the RMM.
This completes the installation process. The Sensor can now be turned over to
those who are responsible for setting up user accounts and operational parameters.
Refer to the online help system for further configuration procedures.