72 | Installing Network Cards in SteelHead GX and xx70, SteelHead SD, SteelCentral, Interceptor 9600, and SteelFusion Core 3500
Installing network add-on cards in 2U appliances
9. For SteelHead GX, CX, SteelHead Interceptor 9600, and SteelFusion Core 3500, plug in the SSD boot
drive cable.
To install the riser assembly without full-length cards
1. Position the riser card edge connector over the server board riser socket.
2. Align the two hooks on the back edge of the riser assembly with the slots on the back of the chassis.
3. Press straight down into riser socket. (see
, letter C.)
Installing and replacing an add-on card in 2U appliances
Follow these instructions to install or replace an add-on card in your 2U appliance.
To install or replace an add-on card
1. Remove the riser assembly.
For instructions, see
“Removing and installing the riser assembly in 2U appliances” on page 69
2. Remove the filler panel from the card slot by pushing it from the inside of the appliance and remove
the screw as shown. (see
, letter A.)
Figure 4-17. Installing a add-in card
3. Insert the card until it seats in the riser connector. (see
, letter B.)
4. Secure the card with a screw as shown. (see
, letter C.)
5. Ensure that all empty card slots have filler panels.
6. Replace the riser assembly. For instructions, see
“Removing and installing the riser assembly in 2U
.