18
1 - I
NSTALLING
THE
S
TEELHEAD
A
PPLIANCE
2. Installing on a Rack
If your model has a bezel, please remove it.
If your model requires rails, attach the rails to each side of the appliance. For details, see the
Documentation Set CD
.
Align the screw holes on the flanges with the screw holes on the rack.
Insert and tighten the screws on each side of the appliance.
NOTE:
Do not cover the air vents on the top of the Model 50/100/200/300. Doing so will cause restricted air flow and
may damage unit or reduce performance. The Model 50/100/200/300 is a desktop model; it does not need to be
mounted to a rack.
3. Connecting the Power
If your model has a master power switch, make sure it is in the off position (on the rear panel).
Plug the power cord or cords into the appliance and an AC outlet.
If your model has a master power switch, press in the master power switch (ON).
Press in the system power switch on the front of the appliance.
CAUTION:
In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you
do not ground the Green/Yellow tab, it can cause electrical shock.
4. Connecting to the Steelhead Appliance
Plug the serial cable into the Console port and a terminal.
Make sure the Console port settings are: 9600, 8 data bits, no parity, 1 stop bit, no flow control.
Start your terminal emulation program (for example, HyperTerminal or Tera Term Pro).
At the login prompt, type
admin
. The default password is
password
.