XH2-240 Hardened Access Points
12
Physical/Environmental Specifications
Operating Temperature: -40 to +55°C / -40 to 131°F, 0-90% humidity, non-condensing.
Dimensions: 11.75 x 8.75 x 3.75 in. / 29.8 x 22.2 x 9.5 cm, including the Ethernet connectors at
the bottom.
Weight: 5.5 lbs. / 2.5 Kg.
Resetting the AP
The reset button returns the AP to factory default settings while rebooting. It is located on the
bottom of the AP, next to the GIG2 Ethernet port. Refer to the image on
page 6
. Use the reset
button as follows:
Unplug the cable from the GIG1/POE port (see
Step 10 on page 11
), but don’t disassemble
the grommet and strain relief.
Remove the screw assembly covering the reset button.
Press the reset button all the way in with a bent paper clip (there should be a faint click) and
keep the button depressed.
Plug the Ethernet cable back in and continue to keep the reset button pressed for 10 seconds.
This triggers the factory default reset during the boot process. If power is being properly
supplied to the AP, the STATUS LED will show blinking green. When the boot has
successfully completed, the LED will be solid green.
Replace the screw assembly covering the reset button to keep water out of the AP.
Snug the grommet and strain relief assembly against the RJ45 plug. Screw the collar onto the
AP securely, to provide a water tight fit.
11