Page 12/ 24
34-81 10/2013
Label
Firm
Version Description
Range
X÷Y
From
X
to
Y
Rev 0.3
Level
Rev 0.5
Level
Hex
Modbus
Address
Base 0
Modbus
Command
Address
40000+
S5
0.3 & 0.5
Energy
saving
stop
on
Thursday
0
÷
23h
50
min.
‐
nu
Pr2
Pr2
0x348
841
Sb5
0.3 & 0.5
Set
back
temperature
on
Thursday
‐
40÷40°F
Pr2
Pr2
0x349
842
E6
0.3 & 0.5
Energy
saving
start
on
Friday
0
÷
23h
50
min.
‐
nu
Pr2
Pr2
0x34A
843
S6
0.3 & 0.5
Energy
saving
stop
on
Friday
0
÷
23h
50
min.
‐
nu
Pr2
Pr2
0x34B
844
Sb6
0.3 & 0.5
Set
back
temperature
on
Friday
‐
40÷40°F
Pr2
Pr2
0x34C
845
E7
0.3 & 0.5
Energy
saving
start
on
Saturday
0
÷
23h
50
min.
‐
nu
Pr2
Pr2
0x34D
846
S7
0.3 & 0.5
Energy
saving
stop
on
Saturday
0
÷
23h
50
min.
‐
nu
Pr2
Pr2
0x34E
847
Sb7
0.3 & 0.5
Set
back
temperature
on
Saturday
‐
40÷40°F
Pr2
Pr2
0x34F
848
WORKING HOURS
ou1
0.3 & 0.5
working
hours
actual
of
relay
1
0÷9999h
Pr1
Pr2
0x350
849
ou2
0.3 & 0.5
working
hours
actual
of
relay
2
0÷9999h
Pr1
Pr2
0x351
850
ou3
0.3 & 0.5
working
hours
actual
of
relay
3
0÷9999h
Pr2
Pr2
0x352
851
oP1
0.3 & 0.5
working
hours
limit
of
relay
1
0÷9999h;
with
0
the
function
is
disabled
Pr2
Pr2
0x353
852
oP2
0.3 & 0.5
working
hours
limit
of
relay
2
0÷9999h;
with
0
the
function
is
disabled
Pr2
Pr2
0x354
853
oP3
0.3 & 0.5
working
hours
limit
of
relay
3
0÷9999h;
with
0
the
function
is
disabled
Pr2
Pr2
0x355
854
OUTPUTS SETTING
1on
0.3 & 0.5
The
output
1
is
always
on
or
depending
on
temperature
rEG=1,1;YES=0,1;
no=0,0
Pr2
Pr2
0x356
855
2on
0.3 & 0.5
The
output
2
is
always
on
or
depending
on
temperature
rEG=1,1;YES=0,1;
no=0,0
Pr2
Pr2
0x357
856
3on
0.3 & 0.5
The
output
3
is
always
on
or
depending
on
temperature
rEG=1,1;YES=0,1;
no=0,0
Pr2
Pr2
0x358
857
OTHER
Adr
0.3 & 0.5
Serial
address
0÷247
Pr2
Pr2
0x359
858
Ptb
0.3 & 0.5
Parameter
map
code
always
=
1
readable
only
Pr2
Pr2
0x35A
859
rEL
0.3 & 0.5
Software
release
5
=
0.5,
3
=
0.3
readable
only
Pr2
Pr2
0x35B
860
i1S
0.5
Analog
output
when
Digital
Input
1
is
activated
4
‐
20mA
Pr2
0x35C
861
i1t
0.5
Analog
output
at
i1S
extra
time
if
Digital
Input
1
is
not
activated
0÷30
sec.
Pr2
0x35D
862
i1d
0.5
Digital
Input
1
Alarm
Delay
0÷255
min.
Pr2
0x35E
863
i1F
0.5
If
Yes,
Digital
Input
1
will
function
as
Alarm.
Operating
only
when
trying
to
call
for
output
1
and
Input
1
is
active,
subject
to
i1d
timer
No;
Yes
Pr2
0x35F
864
i2F
0.5
Digital
Input
2
will
function
only
when
Output
1
is
energized
No;
Yes
Pr2
0x360
865
i3F
0.5
Digital
Input
3
will
function
only
when
Output
1
is
energized,
When
Edi
is
selected,
Output
1
will
open
when
digital
input
3
is
activated
No;
Yes;
Edi
Pr2
0x361
866
oS2
0.5
Output
2
function:
either
temp
relay
or
alarm
relay
Std;
AL
Pr2
0x362
867
0.3 & 0.5
Probe
1
temperature
Degrees
F/C
Pr2
0x100
257
0.3
Probe
1
Information/Status
Normal=512
or
0x0200,
Fault=515
or
0x0203.
Fault
will,
drop
call
for
heat,
buz,
Flash
Yellow
P1,
light
yellow
valve/M
bit
(0,1
on)
probe
failure
Pr2
0x101
258
0.3 & 0.5
Probe
2
temperature
Degrees
F/C
Pr2
0x102
259
0.3
Probe
2
Information/Status
Normal=512
or
0x0200,
Fault=515
or
0x0203.
Fault
will
buz,
Flash
Red
P2
bit (0,1
on)
probe
failure
Pr2
0x103
260
0.3 & 0.5
Probe
3
temperature
Degrees
F/C
Pr2
0x104
261